beautypg.com

Troubleshooting, Condition cause solution – CHAMPION UL-130 Manual User Manual

Page 36

background image

26

Maintenance - Models UH130, UH130B, UH230, UH230B, UL130

Troubleshooting -

Models UH130, UH130B and UH230, UH230B, UL130

Condition

Cause

Solution

Dishwasher will not run.

Low or no water.

Chemicals won’t feed into

dishwasher.

Door not closed.

Main power OFF.

Dishwasher OFF.

Main water supply off.
Fill hose kinked.
Low incoming water pressure
Solenoid valve defective.
Solenoid strainer clogged.
Circuit board fuse blown.

Chemical supply low.
Supply tubing damaged.
Supply tubing kinked.
Pick-up tube clogged
Chemical circuit board fuse blown.

Close door completely.

Check breaker on panel.

Turn dishwasher power switch ON.

Open supply valve.
Straighten fill hose.
Set flowing water pressure to 20-22 PSI.
Install repair kit or replace.
Clean strainer.
Contact service agent..

Refill chemical container.
Replace tubing.
Straighten tubing.
Clean/replace tube.
Contact service agent.

Low water pressure

pumped from wash spray

arms.

Clogged scrap screen.
Clogged spray arms.

Clogged pump intake screen.

Clean scrap screen.
Clean spray arms.

Inspect sump and clean pump intake

screen.

Dishwasher stays in

wash cycle.

Rinse Sentry extends wash mode

for a maximum time of 5-minutes

to allow final rinse water booster

temperature to reach 180˚F/82˚C.

Dishwasher is operating in Extended

Wash Mode.(UH230B, Only)

Raise incoming water temperature.
Adjust/replace final rinse booster

thermistor.

Push EXT WASH button to exit the

Extended Wash mode.

Poor wash results.

Water temperature low.

Thermistor defective.
(See chemicals won’t feed

above.)
(See low or no water above.)
Detergent injector defective.

Chemical circuit board fuse blown.
Wares incorrectly loaded.

in dishrack.

Booster high limit tripped.

Wash tank high limit tripped.

Raise incoming water

temperature to 140°F
Replace thermistor.
(See chemicals won’t feed

above.)
(See low or no water above.)
Replace squeeze tube.

Replace injector motor.

Clean tubing and pick-up.
Contact service agent.
Reposition wares or reduce amount of

wares in dish racks.

Reset or replace high limit.

Reset or replace high limit.

Water has drained out of

the wash tank while the

dishwasher was idle.

Goose-neck loop in drain

hose has been removed.
Drain hose clamp is not

holding the drain hose

in proper position.
Building plumbing does not

provide correct air vent

to prevent siphoning.

Re-route drain hose.

DO NOT STRETCH HOSE
Replace/adjust hose clamp

making sure goose-neck

is maintained.
Contact service Agent

and/or plumber.

This manual is related to the following products: