3
Model UH130, UH130B, UH230, UH230B - Installation
(Single Phase) Electrical Connections -
UH130, UH130B, UH230, UH230B
(continued)
Refer to the connection diagrams below to connect main incoming power to the dishwasher.
L1
L2
L3
N
208-230
VAC
0 VAC
0 VAC
115VAC
GRD
SINGLE PHASE POWER CONNECTION
Models UH130B and UH230B
Do not connect power to L3
HOW TO CONNECT 1 PHASE POWER
! VERY IMPORTANT !
1. Check the data plate on the front of the
dishwasher for the phase of the machine.
.
2. Remove the lower access panel.
3. Pull power connection box forward and out.
4. The Main Terminal Block has connections
for L1, L2, L3, Neutral and Ground.
5. Connect ground, then connect
L1, L2 to 208-230VAC.
6. Connect a current carrying neutral to N.
7. Main Power connections are complete.
If the data plate says the machine is 1 Phase,
then connect a 1 PH power supply.
DO NOT CONNECT POWER TO L3.
THE ELECTRICAL POWER MUST BE A
3-WIRE PLUS GROUND SUPPLY WHICH
INCLUDES A CURRENT CARRYING NEUTRAL.
! VERY IMPORTANT !
SINGLE PHASE UH130B and UH230B
The electrical power must be a
3-wire plus ground supply which
includes a current carrying neutral.
! ATTENTION !
Models UH130 and UH230 without a
built-in booster are equipped with a 4
ft. power cord and plug. These models
require a 115VAC,15A receptacle.
L1
L2
115VAC
15A
4 ft. power cord w/plug supplied
SINGLE PHASE POWER CONNECTION
Model UL100