CHAMPION CH66 Electrical Connection Guide User Manual
Attention electrical installer, Ch44-lr md44-lr, Ch44-rl md44-rl
1
Form No. 115300 rev. 0
Rack Conveyor Models CH44 and MD44
Electrical Utility Connection Guide (CH66, MD66 on reverse side)
! ATTENTION ELECTRICAL INSTALLER !
CH44-LR
MD44-LR
400CFM
150CFM
CH44-RL
MD44-RL
400CFM
150CFM
Main Power —
208-240V/60/3
460-480V/60/3
Vent Fan — 120VAC .5 A MAX signal inside control cabinet
supplies 120VAC to a control relay (supplied by
others) when the dishwasher is ON and OVAC
when the dishwasher is OFF. Power to operate the
vent fan (supplied by others) must be supplied
separately.
Rinse-aid — 120VAC 1.0A MAX signal inside
control cabinet.
Detergent — 120VAC 1.0A MAX signal inside
control cabinet.
VENT FAN
120V .5A
RINSE AID
120V 1A
DETERGENT
120V 1A
A
B
B
C
C
D
D
A
A
A
This manual is related to the following products: