SETUP Menu > Telephony
SLIC > Dialling
Time to dial
Define a timeout for 2N
®
EasyRoute to await more digits to be dialled. The
connection is established when this timeout elapses and no more digits are
accepted.
Tone after disconnection
Define the tone played to the gateway user after the connection is terminated by
the GSM network.
Dial pulse width
Define a pulse width to be identified as one dialling pulse. If the limits are set
incorrectly, pulse dialling cannot be used.
Pause between pulses
Define a period of time to be identified as a delay between pulses.
Minimal pause between digits
Set the minimum interval between two digits dialled.
Minimal On Hook
Set the minimum line current discontinuation to be evaluated as hang-up by
2N
®
EasyRoute. If shorter, the discontinuation is ignored by the gateway.
SLIC > Tones
Dialtone – frequency
Here set the frequency of the dialling tone in [Hz]. You can set up to two
frequencies for a dual tone. The first frequency is obligatory, the other is optional.
Setting options:
100–3,500 Hz
Setting step:
5 Hz
Default setting:
425 Hz for the first tone, the other tone is disabled.
Dialtone – modulation
Set the dialtone modulation, choosing one of the predefined dialtone patterns.
Setting options:
Continuous, 320/320/640/640 (Morse A)
Default setting:
Continuous
Busy tone– frequency
Set the busy tone frequency in [Hz]. You can set up to two frequencies for a dual
tone. The first frequency is obligatory, the other is optional.
Setting options:
100–3,500 Hz
Setting step:
5 Hz
Default setting:
425 Hz for the first tone, the other tone is disabled.