Electrical system – JLG 4017RS Service Manual User Manual
Page 202

Electrical System
9-50
3614RS, 4017RS
MACHINE
CONFIGURATION OUT
OF RANGE – CHECK
ALL SETTINGS
9949
Continuously
Hydraulic functions are prevented
Engine Start is prevented
ECM Power is de-energized to
shutdown engine
UGM detects a parameter range
issue with Machine Setup
Machine Setup
is properly
configured;
Power cycled
CABIN JOYSTICK –
INTERNAL FAILURE
9976
Continuously
Hydraulic functions are prevented
Direction selection shall be neutral
(If FNR configured)
Elobau Joystick configured:
Cabin joystick transmits a DM1
(SPN:FMI)
with 0Xf001:EC, 0Xf002:EC,
0Xf005:EC
Cabin joystick transmitted an
undocumented DM1 (SPN:FMI)
Power cycled
EEPROM VALUE – OUT
OF RANGE
9978
Continuously
Hydraulic functions are prevented
Engine Start is prevented
ECM power is de-energized to
shutdown engine
UGM detects a parameter range
issue with Personalities
Personalities
are properly
configured;
Power cycled
GROUND MODULE
VLOW FET FAILURE
9986
Continuously
Hydraulic functions are prevented
Engine Start is prevented
ECM power is de-energized to
shutdown engine
UGM detects a Low sense FET failure
(all high-sensing digital inputs are
high)
Power cycled
FUNCTIONS LOCKED
OUT – LSI SOFTWARE
VERSION IMPROPER
99151
Continuously
Load Moment Cutout assumed to be
100%
Load Monitoring configured;
LSI System transmitted Major /
Minor Software version that is not
compatible (P0.11 or greater; P1.x
allowed)
Power cycled
LSI FAULTY – SYSTEM
FLASH CRC ERROR
99152
Continuously
Load Moment Cutout assumed to be
100%
Load Monitoring configured;
LSI System reports Fault #1 – CRC
Error in System Flash
Power cycled
LSI FAULTY – DATA
FLASH CRC ERROR
99153
Continuously
Load Moment Cutout assumed to be
100%
Load Monitoring configured;
LSI System reports Fault #2 – CRC
Error in Data Flash
Power cycled
LSI FAULTY – LOAD
CELLS A AND B
DISAGREEMENT
99154
Continuously
Load Moment Cutout assumed to be
100%
Load Monitoring configured;
LSI System reports Fault #3 –
Excessive Data Variance between
Load Cell A and Load Cell B
Power cycled