Electrical system – JLG 4017RS Service Manual User Manual
Page 193

9-41
3614RS, 4017RS
Electrical System
AUXILIARY
FUNCTION-B VALVE –
OPEN CIRCUIT
33199
5000Ms
Auxiliary Function-B is prevented
Continuous Auxiliary Hydraulics is
prevented
Auxiliary Release is prevented
Open-circuit is detected on UGM J2-
20
Power cycled
AUXILIARY
FUNCTION-B VALVE –
SHORT TO GROUND
33200
Continuously
Auxiliary Function-A is prevented
Auxiliary Function-B is prevented
UGM J3-14 Aux Return is disabled
Continuous Auxiliary Hydraulics is
prevented
Auxiliary Release is prevented
Short to ground is detected on UGM
J2-20
Power cycled
STABILIZER/FRAME
LEVEL SPEED VALVE –
OPEN CIRCUIT
33201
5000Ms
Stabilizers are prevented
Frame Level is prevented
Open-circuit is detected on UGM J1-
3
Power cycled
STABILIZER/FRAME
LEVEL SPEED VALVE –
SHORT TO BATTERY
33202
Continuously
Stabilizers are prevented
Frame Level is prevented
UGM J3-5 Stabilizer / Frame Level
Speed Return is disabled
Short to battery is detected on UGM
J1-3
Power cycled
STABILIZER/FRAME
LEVEL SPEED VALVE –
SHORT TO GROUND
33203
Continuously
Stabilizers are prevented
Frame Level is prevented
UGM J3-5 Stabilizer / Frame Level
Speed Return is disabled
Short to ground is detected on UGM
J1-3
Power cycled
LEFT STABILIZER
DOWN VALVE – OPEN
CIRCUIT
33222
5000Ms
Left & Right Stabilizer Down is
prevented
Open circuit is detected on UGM J2-
21
Power cycled
LEFT STABILIZER
DOWN VALVE –
SHORT TO BATTERY
33223
Continuously
Stabilizers are prevented
Frame Level is prevented
Short to battery is detected on UGM
J2-21
Power cycled
LEFT STABILIZER
DOWN VALVE –
SHORT TO GROUND
33224
5000Ms
Left & Right Stabilizer Down is
prevented
Short to ground is detected on UGM
J2-21
Power cycled
LEFT STABILIZER UP
VALVE – OPEN
CIRCUIT
33225
5000Ms
Stabilizers are prevented
Open circuit is detected on UGM J2-
10
Power cycled
LEFT STABILIZER UP
VALVE – SHORT TO
BATTERY
33226
Continuously
Stabilizers are prevented
Frame Level is prevented
Short to battery is detected on UGM
J2-10
Power cycled
LEFT STABILIZER UP
VALVE – SHORT TO
GROUND
33227
5000Ms
Stabilizers are prevented
Short to ground is detected on UGM
J2-10
Power cycled
RIGHT STABILIZER
DOWN VALVE – OPEN
CIRCUIT
33228
5000Ms
Left & Right Stabilizer Down is
prevented
Open circuit is detected on UGM J2-
15
Power cycled
RIGHT STABILIZER
DOWN VALVE –
SHORT TO BATTERY
33229
Continuously
Stabilizers are prevented
Frame Level is prevented
Short to battery is detected on UGM
J2-15
Power cycled
RIGHT STABILIZER
DOWN VALVE –
SHORT TO GROUND
33230
5000Ms
Left & Right Stabilizer Down is
prevented
Short to ground is detected on UGM
J2-15
Power cycled
RIGHT STABILIZER UP
VALVE – OPEN
CIRCUIT
33231
5000Ms
Stabilizers are prevented
Open circuit is detected on UGM J2-
3
Power cycled