4 lsi-can check pt, 5 500 hour - lsi ugm calibration check, Lsi-can check pt – JLG 4017RS Service Manual User Manual
Page 181: 500 hour - lsi ugm calibration check

9-29
3614RS, 4017RS
Electrical System
sounds and the LEDs will flash and perform a sequence
until all are flashing.
9. Perform the LSI- CAN Check PT to finalize the
calibration. Refer to Section 9.10.4, “LSI-CAN Check PT.”
Note: The following procedure MUST BE performed to finalize
the LSI System Calibration.
9.10.4
LSI-CAN Check PT
With the LSI calibrated, the UGM also needs calibrated and
verified.
1. The machine must be on a level surface, wheels steered
straight and park brake ON.
2. Start the machine.
3. Press the “C” and “OK” buttons simultaneously on the
keypad or the analyzer.
4. Go to “ACCESS LEVEL 3” and press “OK”.
5. Enter the proper access code and press “OK”.
6. “ACCESS LEVEL 2” is now visible.
7. Go to “CALIBRATIONS” menu, press “OK”.
8. Scroll to “LSI_CAN CHECK PT”.
9. “SET LSI_CAN CHECK POINT”, use the arrow keys to
change “NO” to “YES”.
10. Follow and execute the screen instructions:
a. “Remove Weights and Attachments”, press “OK”.
b. “Fully deploy stabilizers”, press “OK”.
c. “TELESCOPE IN and FULLY LIFT UP”, press “OK”.
d. “STOP, WAIT ONE MINUTE”, wait at least one minute
and press “OK”.
e. “PRESS ENTER TO SET CHECK POINT”, press “OK”
f. Screen defaults back to “CALIBRATIONS: LSI_CAN
CHECK POINT”.
g. Press “C” for approximate two seconds to return to
normal display screen.
h. LSI Can Check is now complete.
11. Return machine to service.
9.10.5
500 Hour - LSI UGM Calibration Check
1. The machine must be on a level surface, wheels steered
straight and park brake ON.
2. Start machine
3. Press the “C” and “OK” buttons simultaneously on the
keypad or the analyzer.
4. Go to “ACCESS LEVEL 3” and press “OK”.
5. Enter the proper access code and press “OK”.
6. “ACCESS LEVEL 2” is now visible.
7. Go to “OPERATOR TOOLS” menu, press “OK”.
8. Scroll to “LSI_CAN SYSTEM CHECK”.
9. “PERFORM LSI_CAN SYSTEM CHECK?”, use the arrow
keys to change “NO” to “YES”.
10. Follow and execute the screen instructions:
a. “Remove Weights and Attachments”, press “OK”.
b. “Fully deploy stabilizers”, press “OK”.
c. “TELESCOPE IN and FULLY LIFT UP”, press “OK”.
d. “STOP, WAIT ONE MINUTE”, wait at least one minute
and press “OK”.
e. “PRESS ENTER TO START TEST”, press “OK”.
f. Screen will show: “PRESS ENTER TO START TEST:
PASS”.
g. Must receive a “PASS”.
h. Press “C” for approximate two seconds to return to
normal display screen.
i. LSI UGM Calibration Check is now complete.
11. Return machine to service.