JLG G5-18A Service Manual User Manual
Page 171

9-51
G5-18A, 2505H, 25.5
Electrical System
1121
4375
4
Urea pump motor; short circuit to ground
1122
4334
0
Physical range check high for Urea Pump Pressure
1123
4334
1
Physical range check low for Urea Pump Pressure
1124
4334
0
Urea pump pressure sensor; high signal not plausible
1125
4334
1
Urea pump pressure sensor; low signal not plausible
1127
4334
3
Sensor error urea pump pressure; signal range check high
1128
4334
4
Sensor error urea pump pressure; signal range check low
1129
4376
5
SCR reversing valve; open load
1130
4376
12
SCR reversing valve; over temperature
1131
4376
3
SCR reversing valve; short circuit to battery
1132
4376
4
SCR reversing valve; short circuit to ground
1135
3031
0
AdBlue-Tank temperature; maximum exceeded
1136
3031
1
DEF-Tank temperature; below minimum
1138
3031
3
Sensor error urea tank temperature; short circuit to battery
1139
3031
4
Sensor error urea tank temperature; short circuit to ground
1157
97
12
Water in fuel level prefilter; maximum value exceeded
1158
523946
0
Zero fuel calibration injector 1 (in firing order); maximum value exceeded
1159
523947
0
Zero fuel calibration injector 2 (in firing order); maximum value exceeded
1160
523948
0
Zero fuel calibration injector 3 (in firing order); maximum value exceeded
1161
523949
0
Zero fuel calibration injector 4 (in firing order); maximum value exceeded
1162
523950
0
Zero fuel calibration injector 5 (in firing order); maximum value exceeded
1163
523951
0
Zero fuel calibration injector 6 (in firing order); maximum value exceeded
1164
523946
1
Zero fuel calibration injector 1 (in firing order); minimum value exceeded
1165
523947
1
Zero fuel calibration injector 2 (in firing order); minimum value exceeded
1166
523948
1
Zero fuel calibration injector 3 (in firing order); minimum value exceeded
1167
523949
1
Zero fuel calibration injector 4 (in firing order); minimum value exceeded
1168
523950
1
Zero fuel calibration injector 5 (in firing order); minimum value exceeded
1169
523951
1
Zero fuel calibration injector 6 (in firing order); minimum value exceeded
1170
523612
12
Internal software error ECU
1171
175
2
Customer oil temperature; signal un-plausible
1173
523973
14
SCR Tamper detection; derating timer below limit 1
1174
523974
14
SCR Tamper detection; derating timer below limit 2
1175
523975
14
Urea quality; derating timer below limit 1
1176
523976
14
Urea quality; derating timer below limit 2
1177
523977
14
Urea tank level; derating timer below limit 1
1178
523978
14
Urea tank level; derating timer below limit 2
1180
168
0
Physical range check high for battery voltage
1181
168
1
Physical range check low for battery voltage
1182
172
0
Physical range check high for intake air temperature
1183
172
1
Physical range check low for intake air temperature
1187
523980
14
Bad quality of reduction agent detected
1192
523922
12
Over temperature error on burner shut of valve
1193
1180
0
Physical range check high for exhaust gas temperature upstream turbine
1194
1180
1
Physical range check low for exhaust gas temperature upstream turbine
Fault
Codes
SPN
Codes
FMI
Codes
Deutz Description