14 engine diagnostic trouble code emr4, 1 gauge fault code display, Engine diagnostic trouble code emr4 – JLG G5-18A Service Manual User Manual
Page 159: Gauge fault code display

9-39
G5-18A, 2505H, 25.5
Electrical System
9.14
ENGINE DIAGNOSTIC TROUBLE
CODE EMR4
9.14.1
Gauge Fault Code Display
Fault
Codes
SPN
Codes
FMI
Codes
Deutz Description
1
132
11
Air flow sensor load correction factor exceeding the maximum drift limit; plausibility
error
2
132
11
Air flow sensor load correction factor exceeding drift limit; plausibility error
3
132
11
Air flow sensor low idle correction factor exceeding the maximum drift limit
4
132
11
Air flow sensor load correction factor exceeding the maximum drift limit
9
172
2
Sensor ambient air temperature; plausibility error
34
523006
3
Controller mode switch; short circuit to battery
35
523006
4
Controller mode switch; short circuit to ground
36
523923
3
UB1; Short circuit to battery error of actuator relay 1
37
523924
3
UB2; Short circuit to battery error of actuator relay 2
38
523925
3
UB3; Short circuit to battery error of actuator relay 3
39
523926
3
UB4; Short circuit to battery error of actuator relay 4
40
523927
3
UB5; Short circuit to battery error of actuator relay 5
45
168
3
Sensor error battery voltage; signal range check high
46
168
4
Sensor error battery voltage; signal range check low
47
168
2
High battery voltage; warning threshold exceeded
48
168
2
Low battery voltage; warning threshold exceeded
49
597
2
Break lever main switch and break lever redundancy switch status
not plausible
55
523910
14
Air pump doesn't achieve air mass flow set point
56
524013
7
Burner flame unintentional deleted
57
524020
14
Engine power; Not enough oxygen for regeneration
58
523911
0
Burner dosing valve (DV2); over current at the end of the injection phase
59
523911
12
Burner dosing valve (DV2); powerstage over temperature
60
523911
3
Burner dosing valve (DV2); short circuit to battery
61
523911
3
Burner dosing valve (DV2); short circuit to battery on high side
62
523911
4
Burner dosing valve (DV2); short circuit to ground
63
523911
11
Burner dosing valve (DV2); short circuit high side powerstage
64
523912
2
Burner dosing valve (DV2) downstream pressure sensor; plausibility error
66
523912
0
Physical range check high for burner dosing valve (DV2) downstream pressure; shut
off regeneration
69
523912
1
Physical range check low for burner dosing valve (DV2) downstream pressure; shut
off regeneration. When burner injector is actuated, the measured pressure does not
rise above ca. 1250mbarabs
(expected; ca. 2400mbar).
72
523912
3
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
check high
73
523912
4
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
check low
74
523913
3
Sensor error glow plug control diagnostic line voltage; signal range
check high