G5-18A, 2505H, 25.5
Electrical System
LSI Cutout Output -
Short to Battery or
Open Circuit
8518
LSI module detects condition
and OMD reading is 100%
Machine automatically in
LSI Cutout with operation
only available via LSI
Cancel Switch (Creep
Mode operation)
Latched. Check LSI
gauge and sensor wiring
LSI Out of
Calibration
8519
LSI has not been calibrated
via CALIBRATION à LSI
CAN CHECK PT or is not
within tolerance during a
OPERATOR TOOLS à LSI-
CAN SYSTEM CHECK
Activate LSI Cutout if not in
passive mode or not in LSI
calibration mode
Note: If fault is set due to
LSI CAN CHECK PT not
being completed, suppress
LSI Cutout during the
subsequent calibration
procedure
Permit LSI-CAN Display to
control its internal alarm
Not Latched – fault
clears if:
LSI is calibrated or LSI
CAN System Check is
performed and passes
LSI Faulty -
System Flash CRC
Error
99152
The LSI System has
detected a checksum error
with its system flash and is
reporting the issue on a CAN
bus message to the Ground
Module
Default machine to LSI
Cutout (if not in passive
mode or not in LSI
calibration mode) with
operation only available via
LSI Cancel switch (Creep
Mode operation)
Latched. Possibly
replace LSI gauge
LSI Faulty - Data
Flash CRC Error
99153
The LSI System has
detected a checksum error
with its system flash and is
reporting the issue on a CAN
bus message to the Ground
Module
Default machine to LSI
Cutout (if not in passive
mode or not in LSI
calibration mode) with
operation only available via
LSI Override switch (Creep
Mode operation)
Latched. Possibly
replace LSI gauge
LSI Faulty - Load
Cells A and B
Disagreement
99154
The LSI System has
detected a unacceptable
variance in the readings
between Load Cell A and
Load Cell B and is reporting
the issue on a CAN bus
message to the Ground
Module
Default machine to LSI
Cutout (if not in passive
mode or not in LSI
calibration mode) with
operation only available via
LSI Cancel switch (Creep
Mode operation)
Latched. Possibly
replace LSI gauge
Functions Locked
Out – Remote Input
Module Software
Version Improper
99161
The Ground module has
detected that Remote input
module software is not
compatible (Major version
does not match)
Deactivate all
Module Outputs
Latched. Check ground
and remote module
software versions
Help Message
DTC
Trigger / Possible
Symptom
Actions
Latch / Reset
Condition