JLG G5-18A Service Manual User Manual
Page 160

Electrical System
9-40
G5-18A, 2505H, 25.5
75
523913
4
Sensor error glow plug control diagnostic line voltage; signal range
check low
76
523914
5
Glow plug control; open load
77
523914
12
Glow plug control; powerstage over temperature
78
523914
3
Glow plug control; short circuit to battery
79
523914
4
Glow plug control; short circuit to ground
82
1235
14
CAN Bus error passive; warning CAN C
84
639
14
CAN-Bus 0 "BusOff-Status"
85
1231
14
CAN-Bus 1 "BusOff-Status"
86
1235
14
CAN-Bus 2 "BusOff-Status"
88
102
2
Charged air pressure above warning threshold
89
102
2
Charged air pressure above shut off threshold
96
110
3
Sensor error coolant temperature; signal range check high
97
110
4
Sensor error coolant temperature; signal range check low
98
110
0
High coolant temperature; warning threshold exceeded
99
110
0
High coolant temperature; shut off threshold exceeded
101
111
1
Coolant level too low
109
523929
0
Fuel Balance Control integrator injector 1 (in firing order); maximum
value exceeded
110
523930
0
Fuel Balance Control integrator injector 2 (in firing order); maximum
value exceeded
111
523931
0
Fuel Balance Control integrator injector 3 (in firing order); maximum
value exceeded
112
523932
0
Fuel Balance Control integrator injector 4 (in firing order); maximum
value exceeded
113
523933
0
Fuel Balance Control integrator injector 5 (in firing order); maximum
value exceeded
114
523934
0
Fuel Balance Control integrator injector 6 (in firing order); maximum
value exceeded
115
523929
1
Fuel Balance Control integrator injector 1 (in firing order); minimum
value exceeded
116
523930
1
Fuel Balance Control integrator injector 2 (in firing order); minimum
value exceeded
117
523931
1
Fuel Balance Control integrator injector 3 (in firing order); minimum
value exceeded
118
523932
1
Fuel Balance Control integrator injector 4 (in firing order); minimum
value exceeded
119
523933
1
Fuel Balance Control integrator injector 5 (in firing order); minimum
value exceeded
120
523934
1
Fuel Balance Control integrator injector 6 (in firing order); minimum
value exceeded
121
1109
2
Engine shut off demand ignored
122
523698
11
Shut off request from supervisory monitoring function
125
523717
12
Time out Error of CAN-Transmit-Frame AmbCon; Weather environments
126
523603
9
Time out Error of CAN-Receive-Frame AMB; Ambient Temperature Sensor
Fault
Codes
SPN
Codes
FMI
Codes
Deutz Description