2 machine personality settings and function speeds – JLG 1850SJ Service Manual User Manual
Page 296
![background image](/manuals/551716/296/background.png)
SECTION 6 - JLG CONTROL SYSTEM
6-14
– JLG Lift –
3121619
6.2
MACHINE PERSONALITY SETTINGS AND
FUNCTION SPEEDS
NOTE:
Personality settings can be adjusted within the adjustment
range in order to achieve optimum machine performance.
Table 6-4. Machine Personality Settings and Function Speeds
SUBMENU
(DISPLAYED ON
ANALYZER 1ST LINE)
PARAMETER
(DISPLAYED ON ANALYZER 2
ND
LINE)
DESCRIPTION
RANGE
DEFAULT
VALUES
TIME RANGE
(SEC)
DRIVE:
ACCEL X.Xs
Displays/adjusts drive acceleration
0.1 to 5.0 sec
2
DECEL X.Xs
Displays/adjusts drive deceleration
0.1 to 3.0 sec
1.3
MIN forward XX%
Displays/adjusts minimum forward drive speed 0 to 35%
1
MAX forward XXX%
Displays/adjusts maximum forward drive speed 0 to 100%
100
54-58 (see orientation)
MIN reverse XX%
Displays/adjusts minimum reverse drive speed
0 to 35%
1
MAX reverse XXX%
Displays/adjusts maximum reverse drive speed 0 to 100%
100
54-58 (see orientation)
ELEV. MAX XX%
Displays/adjusts maximum drive speed
NOTE: used when elevation cutout switches are
limiting maximum speed
0 to 50%
25
110-112 (see orientation)
CREEP MAX XX%
Displays/adjusts maximum drive speed
NOTE: used when creep switch on pump pot is
active
0 to 50%
35
79-87 (see orientation)
STEER:
MAX SPEED XXX%
Displays/adjusts maximum steer speed.
0 to 100%
100
MAIN LIFT:
ACCEL X.Xs
Displays/adjusts main lift acceleration
0.1 to 5.0 sec
1
DECEL X.Xs
Displays/adjusts main lift deceleration
0.1 to 3.0 sec
1
MIN UP XX%
Displays/adjusts minimum main lift up speed
0 to 60%
20
MAX UP XX%
Displays/adjusts maximum main lift up speed
0 to 100%
80
75-100 (see orientation)
CREEP UP XX%
Displays/adjusts maximum main lift up speed
NOTE: used when creep switch on pump pot is
active
0 to 65%
50
MIN DOWN XX%
Displays/adjusts minimum main lift down
speed
0 to 60%
10
MAX DOWN XXX%
Displays/adjusts maximum main lift down
speed
0 to 100%
60
85-110 (see orientation)
CREEP DOWN XX%
Displays/adjusts maximum main lift down
speed
0 to 75%
45