6036/6036T
Figure 31
OA1080
FUEL FILL
ACCESS DOOR
B. Fuel Tank (Daily Before Operation)
Check fuel supply daily before operation. Open fuel
fill access door with key (Figure 31). Remove fill cap
on tank and fill as required. Replace cap and lock
access door. Total tank capacity is 24 gallons (90,8
liters); useable capacity is 22.5 gallons (85,1 liters).
C. Fuel System Service
1.
Drain water from fuel water separator daily or
10 hour intervals. All engines except Turbo
Charged S/N 3617 and After. Unlock and open
the right rear engine access door. Loosen drain
cock on underside of fuel water separator (Figure
32) and allow all water to drain into a glass until
clear fuel is visible. Tighten drain cock after
draining. Close and lock access door.
Figure 32
OA0292
FUEL WATER
SEPARATOR
DRAIN COCK