Verify all gauges are in working order, Intake strainers, Inspect water and foam tanks – Hale 80FC User Manual
Page 60: Operate pump controls, 5 monthly, Monthly

❑ Preventive Maintenance
60
Pump Ends
p/n: 029-0020-61-0
For example, lubricate all moving parts of the suction, discharge, hose drain,
and multi drain valves and valve linkage with a good grade, lithium base grease.
Note: The PMD valve should be lubricated every six (6) months.
Verify All Gauges are in Working Order
Any gauge that is repeated in another panel, must agree with the gauge on the
operator's panel. Gauges not reading within 10% of the calibrated test gauge
must be removed from service and re-calibrated.
Intake Strainers
❑
Check and clean any debris from the intake.
❑
Flush the pump, if required, using departmental/company procedures.
❑
Repair or replace any damaged strainers.
Inspect Water and Foam Tanks
Visually inspect water and foam tanks for proper level and gauge readings. If
any debris is present, flush the tanks to protect the pump from wear caused by
dirty water or foam concentrate.
Operate Pump Controls
Operate the pump drive controls to verify the pump engages. Verify the indica-
tor lights work properly.
4.5
MONTHLY
Monthly maintenance includes the weekly maintenance procedures plus:
❑
Valve lubrication - see page 59
❑
Gearbox or pedestal option lubrication - see page 61
❑
Checking the pump and drive line bolts - see page 61
❑
Dry vacuum testing - see page 61