Figure 2a-7: spvr priming valves, Figure 2a-8: pvg priming valves, 2a.5 pump shift, automatic (vps / kps) – Hale 80FC User Manual
Page 42

❑ Accessories / Options
42
Section 2a: Accessories
Hale Products, Inc., May 2006, Rev-B
Figure 2a-7: SPVR Priming Valves
❑
The Hale PVG Priming Valve
The PVG is a combination valve and switch and is mounted on the pump
operator’s panel. (See Figure 2a-8: “PVG Priming Valves.”)
Pulling the handle out OPENS the valve and energizes the primer motor.
Pushing the handle in de-energizes the motor and CLOSES the valve.
Figure 2a-8: PVG Priming Valves
2A.5 PUMP SHIFT, AUTOMATIC (VPS / KPS)
The Hale Automatic Pump Shift, Models VPS or KPS, is a remote, pneu-
matically operated, shifting device to shift the pump transmission from
ROAD-to-PUMP and back again. (See Figure 2a-9: “Automatic Pump Shift
Overview,” on page 43.)