Testing – Avaya 555-233-116 User Manual
Page 130

Terminal server installation
555-233-116
130
Issue 4 October 2002
■
Host: C-LAN IP Address
■
Remote Port: C-LAN Ethernet port where IP adjunct service is
offered
■
Local Port: must match the value of Remote Port on the DEFINTY
IP Services screen
6. Press
ENTER
and select Save & Exit to effect the changes.
7. Press
ENTER
again to view the Administration Menu.
8. Select kill to disable the port connection.
9. Repeat the steps for each additional port you want to administer.
10. When administration is complete, from the Connections Menu, select
logout (or press Ctrl D).
11. Close HyperTerminal.
At this point, you have established a connection path from the adjunct
through the IOLAN+ to the C-LAN circuit pack.
Testing
1. On the system management terminal, press
ENTER
to get the login prompt
to the DEFINITY switch.
NOTE:
If you get garbled text, check the baud rate setting on the Port Setup
Menu. You can adjust it up or down.
2. If no login prompt appears, log back into the IOLAN+ through
HyperTerminal.
3. Select Admin mode > stats and press
ENTER
twice.
4. Select users and press
ENTER
.
5. Look at the port that the adjunct is connected to and see if there is any
traffic. If not, check all your connections and administration fields.