TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSES

SOLUTION

Machine not working

Insufficient vacuum in cham-

ber

Machine does not create va-

cuum in chamber

Plexiglas cover does not

close

Insufficient vacuum in bag/

bag does not maintain va-

cuum

Seal seam shows burns and

bubbles

Narrow irregular sealseam

The machine does not seal

Poor sealing

Machine Off

No power supply

Machine damage

Time set insufficient

Vacuum pump performance

insufficient

Cover gasket worn.
Pressure exerted on Plexi-

glas cover during appliance

start up insuf-ficient.
Pump not working

Cover gasket worn

Hinges out of alignment

Bag positioned incorrectly

Bag perforated

Sealing insufficient

Bag defective
Dirty bag open
Bag too big or too small in

relation to product size.

Sealing time too long

Sealing time too short

Sealing bar connection wires

disconnected
Sealing Bar wire broken.

Sealing bar fuse blown.
Seal bag perforated.
Sealing bar dirty.

Sealing time insufficient for

bag basic weight.
Teflon cover worn.
Red silicone worn.

Switch on the machine using the ON/OFF main switch.

Insert the plug in a socket (check the voltage!).
Check power cable to make sure it is intact.
Check fuse PF4 on the power board to make sure they are intact and

inserted correctly.

Contact a Service centre.

Increase evacuation time using the “VAC” key.

Check oil.
Check pump exhaust filter.
Replace cover gasket.
Lower cover with both hands, exerting more pressure.

Change pump fuse PF1 on the power board.

(Contact a Service Centre. )
Change the gasket.

Adjust the cover hinge.

(contact a Service Centre).
Place the bag in the centre on the sealing bar projecting by 20 mm be-

yond it.
Choose a thicker bag and wrap the product with cling film or soft paper.
Increase the sealing time using the “SEAL” key.

Change the bag.
Use a new bag and avoid smearing the opening with oil, grease,

etc.

Choose a bag size suitable for product dimensions.

Decrease the sealing time using the “SEAL” key.

Increase the sealing time using the “SEAL” key.

Check connections or clean the contacts

Change wire.

(Contact a Service Centre)
Change PF2 fuse on power board.
Change seal bag.
Clean sealing bar.

Increase sealing time using “SEAL” key.

Change Teflon cover.
Change red silicone.