VACUUM PACKING MACHINE
CONDITIONNEUSE SOUS VIDE
MAQUINA DE VACÍO
Operating and service manual / Mode d’emploi et d’entretien
Manual de uso y mantenimiento / Ed. 01 - 2011
REV. 00 - Cod.: 1500386
EN
MEDIO - GRANDE
SERVICE MANUAL
Fig. 3
Fig. 4
Fig. 1
Fig. 2
•
B
•
A
WORN TEFLON
TÉFLON USÉ
TEFLÓN
DESGASTADO
•
•
C
NEW
TEFLON BAND
TÉFLON NEUF
TEFLÓN NUE-
•
7.4
ROUTINE MAINTENANCE
7.4.1
REPLACING THE SEALING BAR COVER TEFLON BAND
After a long period of use, a black mark starts appearing on the sealing bar cover Teflon band, so it must be replaced.
To do so, proceed as follows:
1) Remove sealing bar (A) from its seat by releasing the two connection wires (B) (Fig. 1).
2) Detach the brown Teflon cover (C) (Fig. 2).
3) Wipe the sealing bar with alcohol (Fig. 3).
4) Fit a new band (Fig. 4), cutting the excess length at the two ends (Fig. 5).
5) Refit the bar in guide (D - Fig. 6) and reconnect the connection wires (Fig. 7).
ATTENTION!
Do not start Teflon band replacement with the sealing bars hot, as there is danger of burns.
BLACK