7.4.4

CHANGING THE LID GASKET AND RED SILICONE

1) Open the plexiglas cover.

2) Remove cover gasket (F) or the red silicone strip (G) and clean the seats to remove dirt.

3) Insert the new gasket pushing it deep into the cavity all the way.

4) Run a loadless cycle so that the gasket fits firmly into its seat.

D

E

B

• • •

C

7.4.3

CHANGING THE PUMP EXHAUST FILTER

WARNING: This operation must be carried out by qualified personnel.

1) Remove the stainless steel panel on the rear of the machine.
2) 8, 12,18 and 25 mc/h pumps unscrew plug (A) on the pump body using pliers.
3) Remove filter (B) from its seat.
4) Insert the new filter after checking to make sure ’O-ring (C) is in the correct position.
5) Refit the cover by fixing spring (D) on the filter projection (E).