Prospector series poppet valves – Norgren Prospector Series Datasheets User Manual
Page 61
Prospector Series Poppet Valves
Littleton, CO USA
Phone: 303-794-2611
www.norgren.com
VAL-12-61
9 & 10 Solenoid Operators
Standard Solenoid Operators with Cable Grip Connector
for use with Basic 1" & 2" Valves
(Optional for use with Basic 1/4" & 1/2" Valves)
CC = Single solenoid, nonlocking override, 8 WAC & DC.
CR = Twin solenoid, nonlocking override, 8 WAC & DC.
CU = Momentary signal solenoid, nonlocking override, 8 WAC & DC
CK = CCW/24VDC & surge protector cable grip connector.*
Standard Solenoid Operators with Cable Grip Connector
for use with Basic 1/2" & 1/4" Valves
CY = Single solenoid, nonlocking override, 7WAC, 6WDC
CE = Single solenoid, locking override, 7WAC, 6WDC
CS = Single solenoid, no override, 7WAC, 6WDC
CZ = Single solenoid, nonlocking override, 3.5WAC, 2WDC
CF = Single solenoid, locking override, 3.5WAC, 2WDC
DA = Single solenoid, no override, 3.5WAC, 2WDC
CW = Twin solenoid, nonlocking override, 7WAC, 6WDC
CN = Twin solenoid, locking override, 7WAC, 6WDC
CP = Twin solenoid, no override, 7WAC, 6WDC
CV = Momentary signal solenoid, nonlocking override, 7WAC, 6WDC.
Optional Solenoid Operators
C0 = Single, no override, 1/2" conduit.
C1 = Single, locking override, 1/2" conduit.
C2 = Single, no override, junction box.
C3 = Single, locking override, junction box.
C4 = Single, no override, low pressure, 1/2" conduit.
C8 = Single, locking override, high pressure, 1/2" conduit.
CT = Single, no override, high temperature, 1/2" conduit.
D0 = Momentary Signal, no override, 1/2" conduit.
D1 = Momentary Signal, locking override, 1/2" conduit.
D2 = Momentary Signal, no override, junction box.
D3 = Momentary Signal, locking override, junction box.
D4 = Twin, no override, 1/2" conduit.
D5 = Twin, locking override, 1/2" conduit.
D6 = Twin, no override, junction box.
D7 = Twin, locking override, junction box.
D8 = Twin, locking override, high pressure, junction box.
E1 = Single, nonlocking override, 1/2" conduit.
E3 = Single, nonlocking override, junction box.
E8 = Single, nonlocking override, high pressure, 1/2" conduit.
F4 = Momentary Signal, nonlocking override, 1/2" conduit.
F5 = Momentary Signal, nonlocking override, junction box.
F6 = Twin, nonlocking override, 1/2" conduit.
F7 = Twin, nonlocking override, junction box.
X0 = Single, no override, hazardous location.
X1 = Single, locking override, hazardous location.
X2 = Momentary Signal, no override, hazardous location.
X3 = Momentary Signal, locking override, hazardous location.
X4 = Twin, no override, hazardous location.
X5 = Twin, locking override, hazardous location.
9 & 10 Air Operators
A1 = Single, PTF Threads
AA = Single, BSPP Threads
A4 = Twin, PTF Threads
A6 = Momentary signal, PTF Threads
Af = Momentary Signal, BSPP Threads
9 & 10 Manual & Mechanical Operators
MA = Plunger, spring return.
MB = Palm button, spring return.
MC = Hand Lever, horizontal, spring return.
MD = Hand Lever, horizontal, detented.
ME = Hand Lever, vertical, spring return.
MF = Hand Lever, vertical, detented
MG = Clevis Lever, horizontal, spring return.
MH = Clevis Lever, vertical, spring return.
MJ = Roller Lever, horizontal, spring return.
MK = Roller Lever, vertical, spring return.
ML = Foot Pedal, horizontal, spring return.
MM= Foot Pedal, vertical, spring return.
Voltage & Connector Options for Standard Solenoid Operators
Specify the desired valve model number (from pages 8, 10, or 12)
plus the desired option part number from the following tables. When
ordering options for the CN, CP, CR, CU, CV, and CW operators,
specify (Qty 2) after the option part number.
Operator
CD, CE, CN, CP,
DA,
CC,
Optional Voltages
CS, CV, CW, CY
CF, CZ
CR, CU
12V/60Hz/50Hz
54452-34
—
—
24V/60Hz/50Hz
54452-35
54469-24
54458-63
48V/60Hz/50Hz
54452-36
—
—
120V/60Hz, 110V/50Hz
Standard
54469-23
Standard
240V/60Hz, 220V/50Hz
54452-37
—
54458-62
6VDC
—
54469-25
—
12VDC
54452-32
54469-21
54458-64
24VDC
54452-33
Standard
54458-60
110VDC
—
54469-26
—
DA, CE, CF,
CN, CP, CS,
CC,
Optional Connectors
CV, CW, CY, CZ
CR, CU
Cable Grip with Indicator Light
12VDC or AC
—
54257-54
24VDC or AC
54934-09
54257-55
120VDC or AC
54934-03
54257-56
220VDC or AC
—
54257-57
1/2" NPT Conduit
54934-04
54933-18
5-ft. Molded Cord
54934-06
54933-17
5-ft. Molded Cord, Indicator Light,
Surge Protection, Polarity Independent
24VAC or DC
54934-11
54933-08
48VAC or DC
54934-12
54933-10
120VAC or DC
54934-14
54933-12
240VAC or DC
54934-16
54933-14