Prospector Series Poppet Valves
VAL-12-60
Littleton, CO USA
Phone: 303-794-2611
www.norgren.com
Prospector Popped Valve Product Number System
The following chart is intended to be used only as a general guide to the model number system. It is not designed to
"build" model numbers.
POSITION IN MODEL NUMBER
1 Valve Type
A = 2-Port/2-Position, Normally Closed.
B = 2-Port/2-Position, Normally Open.
C = 3-Port/2-Position, Multi-Directional.
D = 3-Port/2-Position, Normally Closed.
E = 3-Port/2-Position, Normally Open.
F = 4-Port/2-Position (4-way).
G = 4-Port/2-Position, (3-way twin, Normally Closed).
7 & 8 Time Delay
00 = None
01 = 0 to 5 seconds.
TDO
Normally closed.
02 = 0 to 5 seconds.
TDR
Normally closed.
03 = 0 to 60 seconds.
TDO
Normally closed.
04 = 0 to 60 seconds.
TDR
Normally closed.
05 = 0 to 60 seconds.
TDOR
Normally closed.
09 = 0 to 60 seconds.
TDO
Normally open.
10 = 0 to 60 seconds.
TDR
Normally open.
22 = 0 to 60 seconds.
Delayed One Shot.
23 = 0 to 60 seconds.
One Shot
Normally closed.
24 = 0 to 60 seconds.
TDO
Normally closed.
2 Mounting Style
1 = Inline, PTF Threads
A = Inline, BSPP Threads
2 = Subbase valve with subbase, PTF Threads
3 = Subbase valve without subbase, PTF Threads
5 Port Size PTF
2 = 1/4"
Ports
3 = 3/8"
Ports
4 = 1/2"
Ports
5 = 3/4"
Ports
6 = 1"
Ports
7 = 1-1/4" Ports
8 = 1-1/2" Ports
9 = 2"
Ports
0 = Subbase valve without subbase.
6 Internal Variation
B = Internal Pilot Supply with unrestricted passage.
C = Internal Pilot Supply with check valve.
E = Sustaining Bleed Operation. Use only with momentary
signal solenoid operator. Has an internal pilot supply.
F = Bleed Operation. Has an internal pilot supply with flow
restrictor. Use only with A1 and A4 air operators.
H = External Pilot Supply.
J = Vacuum Service. Has an external pilot supply
with heavy spring.
K = Sustaining Bleed Operation. Use only with momentary
signal air operator.
3 & 4 Basic Size
01 = 1/4" Basic, (Valve Types D, E, F)
1/2" Basic, (Valve Types A, B, C)
02 = 1/2" Basic, (Valve Types C, D, E, F, G)
1"
Basic, (Valve Types A, B)
03 = 1"
Basic, (Valve Types C, D, E, F, G)
2"
Basic, (Valve Type A)
04 = 1"
Basic, (Valve Types D, E)
2"
Basic, (Valve Type C)
05 = 1/2" Basic, (Valve Type C with 1/4", 3/8" & 1/2" ports)
06 = 1/2" Basic, (Valve Type C with 3/4" port)
07 = 1/2" Basic, (Valve Type D with indicator pin)
08 = 1"
Basic, (Valve Type D with indicator pin)
2"
Basic, (Valve Type C)
21 = 1/2" Basic, (Valve Type F, Valve with subbase)
22 = 1"
Basic, (Valve Type F, Valve with subbase)
23 = 1/2" Basic, (Valve Type F, Valve without subbase)
24 = 1"
Basic, (Valve Type F, Valve without subbase)
Valve Body
Operator
Time
Delay
2
1
3
7 8
9 10
6
-
4 5
-