7.3

ADC_FILT+ Capacitor Effects on THD+N

The value of the capacitor on the ADC_FILT+ pin, 16, affects the low frequency total harmonic distortion +
noise (THD+N) performance of the ADC. Larger capacitor values yield significant improvement in THD+N
at low frequencies.

Figure 33

shows the THD+N versus frequency for the ADC analog input. Plots were tak-

en from the CDB42L51 using an Audio Precision analyzer.

-100

-60

-96

-92

-88

-84

-80

-76

-72

-68

-64

d

B

F

S

20

20k

50

100

200

500

1k

2k

5k

10k

Hz

Figure 33. ADC THD+N vs. Frequency w/Capacitor Effects

1 µF

Legend –
Capacitor Value on ADC_FILT+

10 µF

22 µF