beautypg.com

Switching specifications - i·c® control port, Figure 6. control port timing - i·c, Switching specifications - i²c® control port – Cirrus Logic CS42L51 User Manual

Page 22: Figure 6.control port timing - i²c, Cs42l51 switching specifications - i²c, Control port

background image

22

DS679F1

CS42L51

SWITCHING SPECIFICATIONS - I²C

®

CONTROL PORT

(Inputs: Logic 0 = DGND, Logic 1 = VL, SDA C

L

= 30 pF)

19. Data must be held for sufficient time to bridge the transition time, t

fc

, of SCL.

Parameter Symbol

Min

Max

Unit

SCL Clock Frequency

f

scl

-

100

kHz

RESET

Rising Edge to Start

t

irs

500

-

ns

Bus Free Time Between Transmissions

t

buf

4.7

-

µs

Start Condition Hold Time (prior to first clock pulse)

t

hdst

4.0

-

µs

Clock Low time

t

low

4.7

-

µs

Clock High Time

t

high

4.0

-

µs

Setup Time for Repeated Start Condition

t

sust

4.7

-

µs

SDA Hold Time from SCL Falling

(Note 19)

t

hdd

0

-

µs

SDA Setup time to SCL Rising

t

sud

250

-

ns

Rise Time of SCL and SDA

t

rc

-

1

µs

Fall Time SCL and SDA

t

fc

-

300

ns

Setup Time for Stop Condition

t

susp

4.7

-

µs

Acknowledge Delay from SCL Falling

t

ack

300

3450

ns

t

buf

t

hdst

t

hdst

t

low

t r

t f

t

hdd

t

high

t sud

t sust

t susp

Stop

Start

Start

Stop

Repeated

SDA

SCL

t

irs

RST

Figure 6. Control Port Timing - I²C