beautypg.com

Functions listed alphabetically – Agilent Technologies VXI E1439 User Manual

Page 77

background image

67

Agilent E1439 Programmer's Reference

Functions listed alphabetically

Functions listed alphabetically

age1439_adc_clock

(on page 72)

−determines the ADC clock source

age1439_adc_clock_get

(on page 72)

−gets the ADC clock source

age1439_adc_divider

(on page 73)

−determines which divider is applied to the ADC

clock source

age1439_adc_divider_get

(on page 73)

−gets the module's current clock divider state

age1439_attrib_get

(on page 74)

−gets low-level attributes of current I/O library session.

age1439_cal_get

(on page 75)

−gets last calibration date of specified board

age1439_clock_fs

(on page 76)

−provides the module with the frequency of an external

sample clock

age1439_clock_fs_get

(on page 76)

−gets the current external sample clock frequency

age1439_clock_recover

(on page 77)

−allows recovery from an out-of-spec external sam-

ple clock

age1439_clock_setup

(on page 78)

−sets all timing parameters for commonly used mea-

surement setups

age1439_clock_setup_get

(on page 78)

−gets the current clock setup

age1439_close

(on page 86)

−closes the module's software connection

age1439_combo_setup

(on page 87)

−a quick way to set blocksize, center frequency, and

signal bandwidth with one function

age1439_data_blocksize

(on page 90)

−determines the size of the output data block

age1439_data_blocksize_get

(on page 90)

−gets the output data block size

age1439_data_delay

(on page 90)

−determines FIFO delay in continuous mode

age1439_data_delay_get

(on page 90)

−gets FIFO delay in continuous mode

age1439_data_memsize_get

(on page 88)

−returns module's memory size in megabytes

age1439_data_mode

(on page 90)

−selects block mode or continuous mode

age1439_data_mode_get

(on page 90)

−gets the data mode

age1439_data_port

(on page 90)

−selects VME bus, local bus or fiber interface for

output port transmission

age1439_data_port_get

(on page 90)

−gets the output port designation

age1439_data_resolution

(on page 90)

−selects 12 or 24 bits data resolution

age1439_data_resolution_get

(on page 90)

−gets the data resolution

age1439_data_scale_get

(on page 89)

−gets data scale factor used to convert raw data to

volts

age1439_data_setup

(on page 90)

−sets all format and data output flow parameters

age1439_data_spectral_order

(on page 90)

−specifies the spectral order of the output

data.

age1439_data_spectral_order_get

(on page 90)

−gets the spectral order of the output

data.

age1439_data_type

(on page 90)

−selects real or complex output data

age1439_data_type_get

(on page 90)

−gets output data type

age1439_data_xfersize

(on page 96)

−allows a specified amount of data to be read before

an entire block has been acquired

age1439_data_xfersize_get

(on page 96)

−gets the data transfer size

age1439_driver_debug_level

(on page 97)

−sets the debug level

This manual is related to the following products: