Debugging, Digital processing, Fiber interface – Agilent Technologies VXI E1439 User Manual
Page 72

62
Agilent E1439 Programmer's Reference
Functions listed by functional group
age1439_lbus_mode
−sets the transmission mode of the local bus
age1439_lbus_mode_get
−gets the local bus transmission mode
age1439_lbus_reset
−resets the local bus
age1439_lbus_reset_get
−gets the local bus reset state
Debugging
age1439_cal_get
−gets last calibration date of specified board
age1439_clock_recover
−allows recovery from an out-of-spec external sample
clock
age1439_driver_debug_level
−sets the debug level
age1439_driver_debug_level_get
−gets the debug level
age1439_error_message
−returns error information obtained from function
calls
age1439_error_query
−queries the module for the most recent error
age1439_status_get
−retrieves the module's status register information
age1439_meas_status_get
- retrieves the current measurement status register
information
age1439_self_test
−performs a self-test on the module and returns the result
Digital processing
age1439_combo_setup
−a quick way to set blocksize, center frequency, and sig-
nal bandwidth with one function
age1439_filter_setup
−sets the digital filter bandwidth and decimation filter
parameters
age1439_filter_bw
−selects a signal filter bandwidth
age1439_filter_bw_get
−gets the signal filter bandwidth
age1439_filter_decimate
−enables/disables an extra factor of 2 decimation
age1439_filter_decimate_get
−gets current state of extra decimation
age1439_filter_sync
−synchronizes the decimation filter counter
age1439_frequency_setup
−sets all zoom center frequency parameters
age1439_frequency_center
−sets the center frequency
age1439_frequency_center_get
−gets the current center frequency
age1439_frequency_center_raw
−quickly sets the center frequency
age1439_frequency_center_raw_compute
−quickly calculates the values for
age1439_frequency_center_raw
age1439_frequency_center_raw_get
−gets the raw center frequency
age1439_frequency_cmplxdc
−selects a complex baseband measurement
age1439_frequency_cmplxdc_get
−gets the state of the baseband measurement
mode
age1439_frequency_sync
−prepares the module for a synchronous frequency
change
age1439_frequency_sync_get
−gets the state of the synchronous change mode
Fiber Interface
age1439_fiber_BOF
−controls whether or not automatically generated
BOF events are transmitted
age1439_fiber_BOF_get
−returns the current value of bofEnable
age1439_fiber_clear
−clears all data from the fiber interface FIFO buffers
age1439_fiber_crc
sets up the fiber interface to transmit and receive cyclic