beautypg.com

Age1439_sync_output – Agilent Technologies VXI E1439 User Manual

Page 190

background image

180

Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_sync_output

Selects the output for the sync signal. This description also includes the query function:

age1439_sync_output_get

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_sync_output(ViSession id, ViInt16 syncOutput);
ViStatus age1439_sync_output_get(ViSession
id, ViPInt16 syncOutputPtr);

Note

This command should be used only for specialized custom clock requirements. Most useful clock
setups can be supplied by

age1439_clock_setup

.

Description

This function selects which output the module should use for it’s sync signal.

Parameters

id

is the VXI instrument session pointer returned by the age1439_init function.

syncOutput

AGE1439_SYNC_OUT_OFF

specifies no sync signal output.

AGE1439_SYNC_OUT_BOTH

specifies that the sync signal be output to both the front panel

SMB sync connectors and the VXI backplane.

AGE1439_SYNC_OUT_SMB

specifies that the sync signal be output to the front panel SMB

sync connectors.

AGE1439_SYNC_OUT_VXI

specifies that the sync signal be output to the VXI backplane.

syncOutputPtr

Returns a pointer to the current value of syncOutput.

Return Value

AGE1439_SUCCESS indicates that a function was successful.

Values other than AGE1439_SUCCESS indicate an error condition or other important status
condition. To determine the error message, pass the return value to

“age1439_error_message” on

page 102

.

See Also

“Default values” on page 201

,

“age1439_init” on page 132

,

“age1439_clock_setup” on page 78

,

“age1439_sync_clock” on page 178

,

“age1439_sync_direction” on page 179

,

“Using clock and

sync” in chapter 3

This manual is related to the following products: