Selecting the calibrate laminator tab – HID FARGO HDP8500 User Guide User Manual
Page 120

© 2012 HID Global Corporation. All rights reserved.
120
HDP8500 Industrial Card Printer/Encoder User Guide L001617 rev 1.1
Selecting the Calibrate Laminator tab
The Calibrate Laminator tab is active when the Laminator is automatically detected or when the
Laminator is manually checked (as a Printer Feature on the Configuration tab).
Calibrate button: Sends calibrate Laminator command to Printer. Follow the
instruction on the page for setting up the Printer.
Lamination Module must be warm before sending Calibration option. If not an error will
occur and will trigger the laminator to warm up . Retry the calibration again after
several minutes.
Step
Procedure
Option
1
Select the Calibrate Laminator tab.
a. Remove the Laminate Cartridge
b. Ensure the Laminator Cover is closed.
c. Click on the Calibrate button.
d. Click on the OK button to close the screen.
e.
If successful the printer‟s LCD will reset to ready.
Option
2
NOTE: Calibration of the Ribbon, Film, and Lamination may also be
performed from the DISPLAY ICON.
a. Remove the Laminate Cartridge
b. Ensure the Laminator Cover is closed.
c. Select Lam Calibrate option from the Display.
d.
If successful the printer‟s LCD will reset to ready.