Installation, Utility specifications – Blodgett BLCP User Manual
Page 8
6
Installation
Utility Specifications
eLeCTRiCAL RATinGs
model
voltage
kW
Hz
Phase
max Load (amps)
BLCP-23E
Mini Combi
208/230/240
2.7/3.3/3.6
50/60
1NAC
15
2.7/3.3/3.6
50/60
2AC
15
5.4/6.6/7.2
50/60
3AC
30
400/415
6.6/7.2
50/60
2NAC
15
5.4/5.8
50/60
2AC
15
440/480
5.4/6.5
50/60
2AC
15
BLCP-6E
Mini Combi
208
4.6
50/60
1
23
240
6.1
50/60
1
26
208
6.9
50/60
3
20
240
9.2
50/60
3
23
BLCP-10E
Mini Combi
208/230/240
10.4/12.7/13.8
50/60
3AC
34
10.4/12.7/13.8
50/60
3NAC
34
400/415
12.7/13.8
50/60
3NAC
20
12.7/13.8
50/60
3AC
20
440/480
10.4/12.4
50/60
3AC
18
BCP-61E
BLCP-61E
208
9
60
3
25
240
9
60
3
22
480
9
60
3
11
BCP-101E
BLCP-101E
208
18
60
3
50
240
18
60
3
44
480
18
60
3
22
BCP-102E
BLCP-102E
208
27
60
3
75
240
27
60
3
65
480
27
60
3
33
BCP-202E
BLCP-202E
208
60
60
3
167
240
60
60
3
145
480
60
60
3
73
This manual is related to the following products: