beautypg.com

Allied Telesis AlliedView-EMS 3.11 QoS MANAGER User Manual

Page 112

background image

AlliedView™-EMS 3.11 QoS Manager User’s Guide

Page 112 of 146

Property Name Description

Valid Values

MRTERMINATION

any

This can also be set by entering a 2-

byte hexadecimal number 00-FF.

EIPByte01-16

These parameters each specify the
properties of a single byte field to

match in the Layer 3 header and

data of a non-IPv4 and non-IPv6

packet. The eipbyte01 parameter
must be used as the first byte field,

and additional byte fields must

increment sequentially, for example

eipbyte01, eipbyte02, eipbyte03.
Each field must have a greater offset
than the field that precedes it.

For each byte field you want to

match, specify a byteoffset and a
bytevalue, and optionally, a

bytemask.

byteoffset is a decimal
number in the range 0 to 65.

This specifies the location of
the byte to match. It refers

to the offset from the start
of Layer 3, after the Layer 2

encapsulation format of an

Ethernet frame.

bytevalue is a 2-digit
hexadecimal number. This

specifies the value of the

byte at the frame position
determined by the
byteoffset. The classifier

matches packets that have

this value at this location.

(optional) bytemask is a 2-

digit hexadecimal number.
This specifies an eight-bit

binary mask to apply to the
field. When a bit is set to 1

in the mask, the value of the

bit at the same position in
the byte is used to
determine a match. If the

Each entry can be set by entering
the following value:

, ,

(e.g. 3,AA,FF)