Configure Factory Default

Values

The following procedure returns all AT-S116 Management software
parameters to their factory default values and deletes all tagged and port-
based VLANs on the switch.

Note
The AT-S116 Management software factory default values are
listed in “AT-GS950/48 Default Parameters” on page 393.

Caution

This procedure causes the switch to reboot. The switch does not
forward network traffic during the reboot process. Some network
traffic may be lost.

1. From the main menu on the left side of the page, select the Tools

folder.
The Tools folder expands.

2. From the Tools folder, select Reboot.

The Reboot Page is displayed. See Figure 148 on page 362.

3. Go to the lower part of the page to the Reboot section.

4. In the Reboot Type field, use the pull-down menu to select one of the

following options:

Normal - This setting reloads all configuration parameters that are
saved in flash memory. See “Switch Reboot” on page 362 for more
information when using this selection.

Factory Default - Resets all switch parameters to the factory
default settings, including the IP address, subnet mask, and
gateway address.

Caution

This setting will cause the IP address to be reset to 192.168.1.1.
You will loose connectivity with the switch management software
after the reboot is completed, but you can log in again with this IP
address.

Factory Default Except IP - Resets all switch parameters to the
factory default settings, but retains the current IP address, subnet
mask, and gateway settings saved in flash memory. If the DHCP client
is enabled, it remains enabled after this reset and assignment of the IP