Wesley BC-620-4CA User Manual
Page 74
![background image](/manuals/416189/74/background.png)
70
Curtis 1234/36/38 Manual,
OS
11
4a — MONITOR MENU
Monitor Menu: CUTBACKS
DISPLAY
VARIABLE
RANGE
DESCRIPTION
Motor Temp Cutback
0–100 %
Displays the current available as a result of
MotorTempCutback
0–4096
the motor temperature cutback function.
A value of 100% indicates no cutback in
current.
Controller Temp Cutback 0–100 %
Displays the current available as a result
ControllerTempCutback
0–4096
the controller temperature cutback function.
A value of 100% indicates no cutback in
current.
Undervoltage Cutback
0–100 %
Displays the current available as a result
UndervoltageCutback
0–4096
the undervoltage cutback function.
A value of 100% indicates no cutback in
current.
Overvoltage Cutback
0–100 %
Displays the current available as a result
OvervoltageCutback
0–4096
the overvoltage cutback function.
A value of 100% indicates no cutback in
current.
Monitor Menu: MOTOR TUNING
DISPLAY
VARIABLE
RANGE
DESCRIPTION
Base Speed Captured 0–8000 rpm
Displays the value of the motor base speed
Base_Speed_Captured
0–8000
captured in the most recent acceleration.
This value is used to set the Base
Speed parameter (Program
»
Motor Control
Tuning
»
Field Weakening Control menu),
using the Base Speed set procedure
described on page 62.