beautypg.com

Wesley BC-620-4CA User Manual

Page 103

background image

Curtis 1234/36/38 Manual,

OS

11

99

2 3 J U LY 2 0 0 8 D R A F T

7 — VCL

Status5
*

Bit0 = External Supply Out of Range (Code 69)

*

Bit1 = Motor Temp Sensor Fault (Code 29)

*

Bit2 = VCL Run Time Error (Code 68)

*

Bit3 = +5V Supply Failure (Code 25)

*

Bit4 = OS General (Code 71)

*

Bit5 = PDO Timeout (Code 72)

*

Bit6 = Encoder Fault (Code 36)

*

Bit7 = Stall Detected (Code 73)

Status6
*

Bit0 = Not Used

*

Bit1 = Not Used

*

Bit2 = Emer Rev HPD (Code 47)

*

Bit3 = Not Used

*

Bit4 = Motor Type Fault (Code 89)

*

Bit5 = Not Used

*

Bit6 = Motor Characterization Fault (Code 87)

*

Bit7 = Pump Hardware Fault (Code 97)

model 1298 controllers only

Status7
*

Bit0 = Not Used

*

Bit1 = VCL/OS Mismatch (Code 91)

*

Bit2 = EM Brake Failed to Set (Code 92)

*

Bit3 = Encoder LOS (Limited Operating Strategy) (Code 93)

*

Bit4 = Emer Rev Timeout (Code 94)

*

Bit5 = Dual Severe Fault (Code 75)

*

Bit6 = Fault On Other Traction Controller (Code 74)

*

Bit7 = Illegal Model Number (Code 98)

Status8
*

Bit0 = Pump Overcurrent (Code 95)

model 1298 controllers only

*

Bit1 = Pump BDI (Code 96)

model 1298 controllers only

*

Bit2 = Pump HPD (Code 47)

model 1298 controllers only

*

Bit3 = Dualmotor Parameter Mismatch (Code 99)

*

Bit4 = Not Used

*

Bit5 = Not Used

*

Bit6 = Not Used

*

Bit7 = Not Used