2 — INSTALLATION & WIRING:
Low Current Connections
*
The related VCL columns are vital when writing VCL code (see Section 7).
VCL “functions” are used to access the various I/Os; VCL “references” are
predefined names for specific pins.
Table 2 Low Current Connections
RELATED
VCL
*
PIN
NAME
DESCRIPTION
FUNCTIONS
REFERENCES
1 KSI
Keyswitch input.
Setup_BDI
Keyswitch_Voltage
Provides logic power for
the controller and power
for the coil drivers.
2 Prop. Driver
Proportional driver.
Automate_PWM
Sw_13
This is a coil driver with
Put_PWM
PWM5
current control capability
PD_Current
typically used for a
PD_Output
proportional valve on a
PD_Throttle
hydraulic manifold.
VCL_PD_Throttle
Can also be used as a
digital input.
3 Driver 4
Generic driver #4; can
Automate_PWM
Sw_12
also be used as a digital Put_PWM
PWM4
input. Has low frequency
PWM4_Output
PWM capabilities.
4 Driver 3
Generic driver #3; can
Automate_PWM
Sw_11
also be used as a digital Put_PWM
PWM3
input. Has low frequency
PWM3_Output
PWM capabilities. Typically
used for pump contactor.
5 Driver 2
Generic driver #2; can
Automate_PWM
Sw_10
also be used as a digital Put_PWM
PWM2
input. Has low frequency
PWM2_Output
PWM capabilities and a
slightly higher current
rating.Typically used for
electromagnetic brake.
6 Driver 1
Generic driver #1; can
Automate_PWM
Sw_9
also be used as a digital Put_PWM
PWM1
input. Has low frequency
Set_Interlock
PWM1_Output
PWM capabilities.
Clear_Interlock
Interlock_State
Typically used for main
Main_State
contactor.
7 I/O Ground
Input and output ground
reference.
8 Switch 2
Can be used as generic
Sw_2
Analog 2
switch input #2 or as
Analog2_Input
generic analog input #2.
Typically used as the
motor temperature
analog input.
9 Switch 3
Generic switch input #3.
Sw_3
Typically used as the
interlock switch.
10 Switch 4
Generic switch input #4.
Sw_4
11 Switch 5
Generic switch input #5.
Sw_5