Curtis 1234/36/38 Manual,
OS
11
65
2 3 J U LY 2 0 0 8 D R A F T
4a — MONITOR MENU
Emer Rev
On/Off
Emergency reverse input on or off. The
EMR_State
On/Off
source of the emergency reverse input is
System_Flags1 [Bit 1]
determined by the EMR Type parameter:
from Switch 1 (pin 24) if EMR Type = 0
from VCL function if EMR Type = 1.
Analog 1
0–10.0 V
Voltage at analog 1 (pin 24).
Analog1_Input
0–1023
Analog 2
0–10.0 V
Voltage at analog 2 (pin 8).
Analog2_Input
0–1023
Switch 1
On/Off
Switch 1 on or off (pin 24).
Sw_1
On/Off
Switches [Bit 0]
Switch 2
On/Off
Switch 2 on or off (pin 8).
Sw_2
On/Off
Switches [Bit 1]
Switch 3
On/Off
Switch 3 on or off (pin 9).
Sw_3
On/Off
Switches [Bit 2]
Switch 4
On/Off
Switch 4 on or off (pin 10).
Sw_4
On/Off
Switches [Bit 3]
Switch 5
On/Off
Switch 5 on or off (pin 11).
Sw_5
On/Off
Switches [Bit 4]
Switch 6
On/Off
Switch 6 on or off (pin 12).
Sw_6
On/Off
Switches [Bit 5]
Switch 7
On/Off
Switch 7 on or off (pin 22).
Sw_7
On/Off
Switches [Bit 6]
Switch 8
On/Off
Switch 8 on or off (pin 33).
Sw_8
On/Off
Switches [Bit 7]
Driver 1 Input
On/Off
Driver 1 input on or off (pin 6).
Sw_9
On/Off
Switches [Bit 8]
Driver 2 Input
On/Off
Driver 2 input on or off (pin 5).
Sw_10
On/Off
Switches [Bit 9]
Monitor Menu: INPUTS,
cont’d
DISPLAY
VARIABLE
RANGE