beautypg.com

Wesley BC-620-4CA User Manual

Page 69

background image

Curtis 1234/36/38 Manual,

OS

11

65

2 3 J U LY 2 0 0 8 D R A F T

4a — MONITOR MENU

Emer Rev

On/Off

Emergency reverse input on or off. The

EMR_State

On/Off

source of the emergency reverse input is

System_Flags1 [Bit 1]

determined by the EMR Type parameter:

from Switch 1 (pin 24) if EMR Type = 0

from VCL function if EMR Type = 1.

Analog 1

0–10.0 V

Voltage at analog 1 (pin 24).

Analog1_Input

0–1023

Analog 2

0–10.0 V

Voltage at analog 2 (pin 8).

Analog2_Input

0–1023

Switch 1

On/Off

Switch 1 on or off (pin 24).

Sw_1

On/Off

Switches [Bit 0]

Switch 2

On/Off

Switch 2 on or off (pin 8).

Sw_2

On/Off

Switches [Bit 1]

Switch 3

On/Off

Switch 3 on or off (pin 9).

Sw_3

On/Off

Switches [Bit 2]

Switch 4

On/Off

Switch 4 on or off (pin 10).

Sw_4

On/Off

Switches [Bit 3]

Switch 5

On/Off

Switch 5 on or off (pin 11).

Sw_5

On/Off

Switches [Bit 4]

Switch 6

On/Off

Switch 6 on or off (pin 12).

Sw_6

On/Off

Switches [Bit 5]

Switch 7

On/Off

Switch 7 on or off (pin 22).

Sw_7

On/Off

Switches [Bit 6]

Switch 8

On/Off

Switch 8 on or off (pin 33).

Sw_8

On/Off

Switches [Bit 7]

Driver 1 Input

On/Off

Driver 1 input on or off (pin 6).

Sw_9

On/Off

Switches [Bit 8]

Driver 2 Input

On/Off

Driver 2 input on or off (pin 5).

Sw_10

On/Off

Switches [Bit 9]

Monitor Menu: INPUTS,

cont’d

DISPLAY

VARIABLE

RANGE

DESCRIPTION