beautypg.com

Wesley BC-620-4CA User Manual

Page 24

background image

20

Curtis 1234/36/38 Manual,

OS

11

Analog inputs

Two control lines can be used as analog inputs. Both inputs are protected
against shorts to B+ or B-.

Typically Analog 2 is used as the input for the motor temperature sensor.

This input provides a constant current appropriate for a thermistor sensor. Some
standard predefined motor temperature sensors are supported in software (see
Sensor Type parameter, page 50). Note: The industry standard KTY tempera-
ture sensors are silicon temperature sensors with a polarity band; the polarity
band of a KTY sensor must be the end connected to I/O Ground
(pin 7).

These lines can also be used as digital inputs, and are included in that

group as well.

2 — INSTALLATION & WIRING:

I/O Signal Specifications

Analog output

A single line is available as a low power analog output and is intended to drive
instrumentation such as a battery discharge indicator. This output is generated
from a filtered PWM signal and has about 1% ripple. The 2% settling time
is <25ms for a 0–5V step and <30 ms for a 0–10V step. This output line is
protected against shorts to B+ or B-.

POWER SUPPLY OUTPUT SPECIFICATIONS

OUTPUT

OUTPUT

PROTECTED

ESD

SIGNAL

NAME

PIN

VOLTAGE

CURRENT

VOLTAGE

TOLERANCE

+12V Out

25 11.5 to 14.5 V 200 mA max

- 1 V to

± 8 kV (air

+5V Out

26 5 V ±5%

(combined total) (MaxV + 10 V) discharge)

I/O Ground

7

n/a

500 mA max

not protected

ANALOG INPUT SPECIFICATIONS

OPERATING

INPUT

PROTECTED

ESD

SIGNAL

NAME

PIN

VOLTAGE

IMPEDANCE

VOLTAGE

TOLERANCE

Analog 1

24

0 to 10 V in 24-36V models:

- 10 V to

± 8 kV (air

Analog 2

8

1024 steps

about 7.1 kΩ

(MaxV + 10 V) discharge)

36-48V models:

about 11.0 kΩ

48-80V models:

about 26.0 kΩ

ANALOG OUTPUT SPECIFICATIONS

OUTPUT

OUTPUT

PROTECTED

ESD

SIGNAL

NAME

PIN

VOLTAGE

IMPEDANCE

VOLTAGE

TOLERANCE

Analog Out

30 0 to 10 V

Source: 100 Ω

- 1 V to

± 8 kV (air

Sink: 66 kΩ

(MaxV + 10 V) discharge)

Power supply outputs

Two lines provide auxiliary output power for low power circuits such as elec-
tronic throttles, LED indicators, displays, position encoder, and remote I/O
boards. I/O Ground (at pin 7) is the return line for these low power devices.
Both power supply outputs are protected against shorts to B+ or B-.