4a — MONITOR MENU
Monitor Menu: CONTROLLER
DISPLAY
VARIABLE
RANGE
DESCRIPTION
Current (RMS)
0–1000 A
RMS current of the controller, taking all
Current_RMS
0–10000
three phases into account.
Modulation Depth
0–100 %
Percentage of available voltage being used.
Modulation_Depth
0–1182
Frequency
-300–300 Hz
Controller electrical frequency.
Frequency
-18000–18000
Temperature
-100–300 °C
Controller internal temperature.
Controller_Temperature
-1000–3000
Main State
0–10
Main contactor state:
Main_State
0–10
0 = open
1 = precharge
2 = weldcheck
3 = closingdelay
4 = missingcheck
5 = closed (when Main Enable = On)
6 = delay
7 = arccheck
8 = opendelay
9 = fault
10= closed (when Main Enable = Off).
Regen
On/Off
On when regen braking is taking place;
Regen_State
On/Off
Off when it is not.
System_Flags1 [Bit 2]
VCL Error Module
0–65536
A VCL Runtime Error (fault code 68) will
Last_VCL_Error_Module
0–65536
store additional information about the
cause of a VCL runtime error in the VCL
VCL Error
0–65536
Error Module and VCL Error variables. The
Last_VCL_Error
0–65536
resulting non-zero values can be compared
to the runtime VCL module ID and error
code definitions listed in the controller’s OS
SysInfo file, which should help pinpoint the
VCL error that caused the runtime error.
Motor Characterization Error 0–65536
A Motor Characterization Error (fault code 87)
Motor_Characterization_Error
0–65536
will store additional information in the Motor
Characterization Error variable:
0 = none
1 = encoder signal seen but unable to
determine step size; must set up
Encoder Step Size manually
2 = motor temp sensor fault
3 = motor temp hot cutback fault
4 = controller overtemp cutback fault
5 = controller undertemp cutback fault
6 = undervoltage cutback fault
7 = severe overvoltage fault
8 = encoder signal not seen, or one or
both channels missing
9 = motor parameters out of character-
ization range.