Curtis 1234/36/38 Manual,
OS
11
109
2 3 J U LY 2 0 0 8 D R A F T
7 — VCL
START_PUMP()
This function is used to turn on the pump lift contactor. If the 1311 parameter
Drivers
»
Hydraulic Contactor
»
Contactor Enable = On (VCL HydraulicContactorEnable
bit variable = On), the VCL function Start_Pump() will turn on the pump lift contactor
(Driver 3).
When HydraulicContactorEnable = On and neither Start_Pump() nor Stop_
Pump() has been called, the pump lift contactor is Off.
Syntax
Start_Pump()
Parameters
None.
Returns
0 – Pump start function not enabled.
1 – Pump start function successfully enabled.
Error Codes
None.
Example
Start_Pump()
This will turn on the pump lift contactor.
STOP_PUMP()
This function is used to turn off the pump lift contactor. If the 1311 parameter
Drivers
»
Hydraulic Contactor
»
Contactor Enable = On (VCL HydraulicContactorEnable
bit variable = On), the VCL function Start_Pump() will turn off the pump lift contactor
(Driver 3).
When HydraulicContactorEnable = On and neither Start_Pump() nor Stop_
Pump() has been called, the pump lift contactor is Off.
Syntax
Stop_Pump()
Parameters
None.
Returns
0 – Pump stop function not enabled.
1 – Pump stop function successfully enabled.
Error Codes
None.
Example
Stop_Pump()
This will turn off the pump lift contactor.