Wesley BC-620-4CA User Manual
Page 36
![background image](/manuals/416189/36/background.png)
32
Curtis 1234/36/38 Manual,
OS
11
3 — PROGRAMMABLE PARAMETERS:
Fine Tuning Parameters
(SPEED MODE)
1 – SPEED MODE
FINE TUNING MENU
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
Partial Decel Rate
0.1–30.0 sec.
Sets the rate (in seconds) that is used to slow down the vehicle
Partial_Decel_Rate_SpdM
100–30000
when the throttle is reduced without being released to neutral.
Larger values represent slower response.
HS (High Speed)
0–100 %
Sets the percentage of the Typical Max Speed (page 53) above which
HS
0–32767
the “HS” parameters will be used.
LS (Low Speed)
0–100 %
Sets the percentage of the Typical Max Speed (page 53) below which
LS
0–32767
the “LS” parameters will be used.
Reversal Soften
0–100 %
Larger values create a softer reversal from regen braking to drive
Reversal Soften_SpdM
0–3000
when near zero speed. This helps soften the transition when the regen
and drive current limits are set to different values.
Max Speed Accel
0.1–30.0 sec
In some applications, the Max Speed value is changed frequently,
Max_Speed_Accel_SpdM
100–30000
through VCL or over the CAN bus. The Max Speed Accel parameter
controls the rate at which the maximum speed setpoint is allowed to
change when the value of Max Speed is raised. The rate set by this
parameter is the time to ramp from 0 rpm to Typical Max Speed rpm.
For example, suppose Max Speed is raised from 1000 rpm to 4000
rpm. If Typical Max Speed is 5000 rpm, and the rate is 10.0 seconds,
it will take 10.0 * (4000–1000) / 5000 = 6.0 seconds to ramp from 1000
rpm to 4000 rpm.
Max Speed Decel
0.1–30.0 sec
This parameter works like the Max Speed Accel parameter, except that
Max_Speed_Decel_SpdM
100–30000
it controls the rate at which the maximum speed setpoint is allowed to
change when the value of Max Speed is lowered.
For example, suppose you change Max Speed from 4500 rpm
to 2500 rpm. If Typical Max Speed is 5000 rpm, and the rate is 5.0
seconds, it will take 5.0 * (4500–2500) / 5000 = 2.0 seconds to ramp
from 4500 rpm to 2500 rpm.
Fig. 7
Response rate
diagram.
In this example,
HS = 70%,
LS = 30%,
Typ Max Spd = 5000 rpm.