Campbell Scientific CR7 Measurement and Control System User Manual
Page 90
SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
8-8
*
1
Table 1 Programs
01:
1
Sec. Execution Interval
01:
P17
Panel Temperature
01:
1
IN Card
02:
16
Loc [:PANL TEMP]
02:
P1
Volt (SE)
01:
6
Reps
02:
8
5000 mV slow Range
03:
1
IN Card
04:
1
IN Chan
05:
1
Loc [:W1 ]
06:
.018
Mult
07:
0
Offset
03:
P14
Thermocouple Temp (DIFF)
01:
4
Reps
02:
15
150 mV fast Range
03:
1
IN Card
04:
7
IN Chan
05:
2
Type E (Chromel-Constantan)
06:
16
Ref Temp Loc PANL TEMP
07:
7
Loc [:Ta2 ]
08:
1
Mult
09:
0
Offset
04:
P37
Z=X*F
01:
1
X Loc W1
02:
1.22
F
03:
1
Z Loc [:W1 ]
05:
P37
Z=X*F
01:
4
X Loc W2
02:
1.22
F
03:
4
Z Loc [:W2 ]
06:
P54
Block Move
01:
5
No. of Values
02:
4
First Source Loc W2
03:
1
Source Step
04:
11
First Destination Loc [:W2 ]
05:
1
Destination Step
07:
P31
Z=X
01:
9
X Loc
02:
4
Z Loc [:W2 ]
08:
P57
Wet/Dry Bulb Temp to VP
01:
17
Pressure Loc
02:
9
Dry Bulb Temp Loc
03:
10
Wet Bulb Temp Loc
04:
5
Loc [:U2 ]
09:
P57
Wet/Dry Bulb Temp to VP
01:
17
Pressure Loc
02:
14
Dry Bulb Temp Loc
03:
15
Wet Bulb Temp Loc Tw2
04:
15
Loc [:Tw2 ]
10:
P92
If time is
01:
0
minutes into a
02:
30
minute interval
03:
10
Set high Flag 0 (output)
11:
P62
CV/CR
01:
5
No. of Input Values
02:
5
No. of Means
03:
5
No. of Variances
04:
0
No. of Std. Dev.
05:
4
No. of Covariances
06:
2
No. of Correlations
07:
300
Samples per Average
08:
1
First Sample Loc W1
09:
20
Loc [:MEAN (W1)]
12:
P62
CV/CR
01:
5
No. of Input Values
02:
5
No. of Means
03:
5
No. of Variances
04:
0
No. of Std. Dev.
05:
4
No. of Covariances
06:
2
No. of Correlations
07:
300
Samples per Average
08:
11
First Sample Loc W2
09:
36
Loc [:MEAN (W2)]
13:
P77
Real Time
01:
110
Day,Hour-Minute
14:
P70
Sample
01:
35
Reps
02:
20
Loc MEAN (W1)
15:
P
End Table 1
*
A
Mode 10 Memory Allocation
01:
54
Input Locations
02:
79
Intermediate Locations