iii
PROGRAMMING EXAMPLES
7.
MEASUREMENT PROGRAMMING EXAMPLES
7.1
Single Ended Voltage-LI200S Silicon Pyranometer ................................................................7-1
7.2
Differential Voltage Measurement...........................................................................................7-1
7.3
Thermocouple Temperatures Using 723-T Reference ...........................................................7-2
7.4
Thermocouple Temperatures Using an External Reference Junction ....................................7-2
7.5
Thermocouples for Differential Temperature Measurement ...................................................7-3
7.6
Temperature with Calibrated Thermocouples.........................................................................7-4
7.7
107 Temperature Probe ..........................................................................................................7-5
7.8
207 Temperature and RH Probe.............................................................................................7-5
7.9
Anemometer with Photochopper Output .................................................................................7-6
7.10
Tipping Bucket Raingage with Long Leads.............................................................................7-6
7.11
100 ohm PRT in 4 Wire Half-Bridge........................................................................................7-7
7.12
100 ohm PRT in 3 Wire Half-Bridge........................................................................................7-8
7.13
100 ohm PRT in 4 Wire Full-Bridge ........................................................................................7-9
7.14
Pressure Transducer-4 Wire Full-Bridge ..............................................................................7-10
7.15
Lysimeter-6 Wire Load Cell...................................................................................................7-11
7.16
227 Gypsum Soil Moisture Block ..........................................................................................7-13
7.17
Nonlinear Thermistor in Half Bridge (CSI Model 101)...........................................................7-14
8.
PROCESSING AND PROGRAM CONTROL EXAMPLES
8.1
Computation of Running Average ...........................................................................................8-1
8.2
Rainfall Intensity ......................................................................................................................8-2
8.3
SUB 1 Minute Output Interval Synched to Real Time .............................................................8-3
8.4
Analog Output to Strip Chart ...................................................................................................8-4
8.5
Converting 0-360 Wind Direction Output to 0-540 for Strip Chart...........................................8-5
8.6
Covariance Correlation Programming Example......................................................................8-6
INSTRUCTIONS
9.
INPUT/OUTPUT INSTRUCTIONS
.....................................................................................9-1
10. PROCESSING INSTRUCTIONS
......................................................................................10-1
11. OUTPUT PROCESSING INSTRUCTIONS
...................................................................11-1
12. PROGRAM CONTROL INSTRUCTIONS
......................................................................12-1
MEASUREMENTS
13. CR7 MEASUREMENTS
13.1
Fast and Slow Measurement Sequence ...............................................................................13-1
13.2
Single-Ended and Differential Voltage Measurements .........................................................13-1
13.3
The Effect of Sensor Lead Length on the Signal Settling Time ............................................13-3
13.4
Thermocouple Measurements ............................................................................................13-11
13.5
Bridge Resistance Measurements ......................................................................................13-15
13.6
Resistance Measurements Requiring AC Excitation ..........................................................13-19
13.7
Pulse Count Measurements................................................................................................13-20