Cr7 index – Campbell Scientific CR7 Measurement and Control System User Manual
Page 179

I-1
CR7 INDEX
-6999 9-1
-99999 9-1
* Modes, see Modes
1/X [Instruction 42] 10-2
101 Thermistor Probe
Programming example 7-14
107 Thermistor Probe [Instruction 11] 9-5
Calculating lead lengths 13-7
Programming examples 7-5
207 Relative Humidity Probe [Instruction 12] 9-5
Programming example 7-5
227 Soil Moisture Block
Programming example 7-13
3 Wire Half Bridge [Instruction 7] 9-4
Programming example 7-8
4 Wire Full Bridge [Instruction 6] 9-4
Programming example 7-9, 7-10
6 Wire Full Bridge [Instruction 9] 9-4
Programming example 7-11
5th Order Polynomial [Instruction 55] 10-5
Programming example 7-13, 7-14
700 Control Module OV-1
720 I/O Module OV-2
723-T, Reference junction temperature with 13-11
A
A*X + B Scaling Array [Instruction 53] 10-4
ABS(X) [Instruction 43] 10-3
AC excitation, Resistance measurements
requiring 13-19
AC Half Bridge [Instruction 5] 9-3, 13-19
Programming example 7-13
AC Noise, Eliminating 13-1
Activate Serial Data Output [Instruction 96] 12-6
Analog Input voltage, Maximum 13-2
Analog Output [Instruction 21] 9-8
Programming example 8-5
Analog to Digital (A/D) conversion 13-1
AND construction, Logical 3-5
Arctan [Instruction 66] 10-10
ASCII
Characters 6-4
Definition A-1
Dumping (in Telecommunications Mode) 5-3
Program listing (*D Mode) 1-7
Standard 6-4
Transmission 6-4
Average - [Instruction 71] 11-3
Computing running 8-1
B
Battery power options
External 14-4
Caution vi
Sealed lead acid 14-2
Solar panels with 21XL 14-3
Vehicle power supply 14-4
Battery Voltage - [Instruction 10] 9-5
Baud rate
Definition A-1, 6-4
Output Codes 4-1
Setting between I/O and Control Module 15-6
Begin case statement [Instruction 93] 12-5
Binary telecommunications C-1
Block Move - [Instruction 54] 10-4
Programming example 8-1
Branching, Logical AND or OR 3-4
Bridge measurements 13-16
3 Wire Half Bridge 100 ohm PRT 7-8
4 Wire Full Bridge (Pressure Transducer) 7-10
4 Wire Full Bridge 100 ohm PRT 7-9
4 Wire Half Bridge 100 ohm PRT 7-7
6 Wire Full Bridge (Lysimeter) 7-11
Comparison of bridge measurement
instructions 13-17
Diagram of bridge measuring circuits 13-16
AC excitation 13-19
Bridge Transform - [Instruction 59] 10-6
Programming example 7-9
C
Cables/Leads
Avoid PVC insulated conductors 13-9
Determining lead capacitance 13-4
Lead length on signal settling time,
Effect of 13-3
Tipping bucket rain gauge with long leads
programming example 7-6
Card number 3-1
Cassette recorder 4-4
Cautionary Notes vi
Checksum 5-2
Clock
Setting/displaying time (*5 Mode) 1-2
Programming example OV-13
Common mode range 13-2, 14-6