CPEC200 Closed-Path Eddy-Covariance System

Public variable

mode_status describes the basic operating state of the

CPEC200. Verify

mode_status = Normal EC mode. See Appendix A,

CPEC200 Diagnostics, for further information.

Public variable

cpec_status gives an overall status for the entire system. If

there are no problems detected,

cpec_status will report CPEC is OK. See

Appendix A, CPEC200 Diagnostics, for further information.

If the CPEC200 was not configured with the optional valve module, the

installation is now complete. If the valve module is installed, use the zero/span

capability of the CPEC200 as described in Section 6, Zero and Span.

6. Zero and Span

6.1 Introduction

The EC155 must be zeroed and spanned periodically to maintain its accuracy.

This requires the user to supply cylinders of zero air and CO

2

span gas and

appropriate regulators.

Use high-quality gases for the zero and CO

2

span. The zero gas

must be free of significant water vapor and CO

2

. The CO

2

span

gas should have a well-known concentration of CO

2

, balanced in

air (not nitrogen).

There are three ways that the EC155 can be zeroed and spanned:

1. The EC155 can be zeroed and spanned independently of the CPEC200

system, per the instructions in the EC155 CO

2

and H

2

O Closed-Path

Gas Analyzer Manual. This option can zero and span both CO

2

and

H

2

O. This is the only choice if the CPEC200 was configured without

the optional valve module.

2. The EC155 zero and CO

2

span may be performed automatically by the

CPEC200 system. This requires the CPEC200 be configured with the

optional valve module. This method can zero both CO

2

and H

2

O but

can span only CO

2

. Further details for this option are given in Section

6.2, Automatic Zero and Span.

3. The optional valve module allows the EC155 zero and span to be

performed manually at the field site. If the CPEC200 has been

configured with an internet connection, the manual zero and span may

also be done remotely. Although CO

2

and H

2

O zero, and CO

2

span

may be performed remotely, H

2

O span requires the dewpoint

generator to be brought to the field site. Further details for this option

are given in Section 6.3, Manual Zero and Span.

See Section 5.2.2, Zero

/

Span, for details on plumbing connections to zero and

span the EC155 while installed in the CPEC200. The following sections give

details on configuring the CPEC200 for either automatic or manual zero and

span.

NOTE

33