beautypg.com

2 maximum temperature alarm, 3 temperature sensor failure, 4 temprx empfang on/off – Flytec 6040 * User Manual

Page 27: 7 temperature transmitter flytec tt34, Maximum temperature alarm, Temperature sensor failure, Temprx empfang on/off, Temperature transmitter flytec tt34

background image

Operation Manual FLYTEC 6040 GPS

25


2.6.1.2 Maximum Temperature Alarm

The maximum envelope temperature is a default value recommended by the manufacturer and can
not be manipulated. If the pilot reaches the maximum alarm level a temperature alarm will always
go on. The alarm sound will be heard as a constant tone until the maximum envelope temperature
is not reached any more.

The maximum envelope alarm can not be switched off


2.6.1.3 Temperature sensor failure

If the temperature sensor is not working properly any more, a symbol which indicates the
interruption --¦ ¦-- appear in the envelope temp display. Simultanously the temperature alarm goes
on.

2.6.1.4 TempRx Empfang On/Off

In case no temperature transmission unit is in
Use, the radio receive function for the TT34 can be
switched off, by pressing the TempRx key for a
short time. The switched-off status is indicated in
the temperature reception display by “Off”

2.7 Temperature transmitter FLYTEC TT34


The radio transmission unit TTT34 is operating with a 9-V battery. The temperature transmission is
switched on automatically as soon as the differential temperature between the instrument and the
envelope temperature (factory default value) is being recognized by the TT34 unit.
.
Switch on: Differential temperature of > 15ºC or abs. > 50ºC
Switch off: Differential temperature of < 15ºC and abs. < 50ºC


The operation time fort the Alcaline-battery lasts for
about 3 years and with a full operation time of around
200 hours.. The battery status is indicated in the
main display as well as in the windlayer




The TT34 unit is mounted on the outside of the envelop. The temperature sensor must be
laid to the inner side of the envelope and must be solidly mounted in a way that he touches
the envelope tissue.










The mounting must be carried out exactly according to the regulation. (See attachment
on page 55)

km/h

3

4

2

m/s

Int

5.0

49

P1

60

50

1

N

E