Appendix F - Error Codes
DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)
Page 97
Code
Calculated
Sn where n
= sum of
the
following
Description
Meaning
+2
Keypad calibration not complete
(Status stored in BPK)
After reset, calibration should be
redone (but really only status has been
lost)
+4
MSR key pairing not completed
Need to perform action.
Permanent.
+8
Tamper sensors not activated
Status set after BPK initialized.
Cleared once sensors activated.
Stored in BPK
+16
Keypad activation sequence not sent
Need to perform action.
Permanent.
+32
Keypad tamper detected during power up
(Threshold stored in BPK)
Retry. Keypad may have shifted or
been modified. Something nearby may
be interfering. Keypad calibration bad
or not performed yet.
Table 3-91 - Common "S" Error Codes
Common
S codes
Description
Meaning
S63/S31
Usually new unit
Usually occurs after battery reset or battery
power loss
S43/S35
Keypad calibration not complete
(Status stored in BPK)
After reset, calibration should be redone
(but really only status has been lost)
F.3 C Codes
Table 3-92 - "C" Error Codes
Code Calculated
Cn where n = sum of the
following
Description
+1
Mfg Unbind certificate not loaded
+2
Device CA certificate not loaded
+4
PIN CA certificate not loaded
+8
MSR CA certificate not loaded