7 report 0x07 – display message, Report 0x07 – display message, 3 - command set – MagTek DynaPro Mini Programmer's99875629 User Manual
Page 34
3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)
Page 34
Bit
7
6
5
4
3
2
1
0
Enter
Right
Middle
Left
Byte 4
Tones:
Start Transaction Tones Only:
0 = No sound
1 = One beep
2 = Two beeps
Start Transaction & Timeout Tones:
100 = No start beep, no timeout
101 = One start beep, no timeout
102 = Two start beep, no timeout
3.4.7 Report 0x07 – Display Message
This command causes the device to display a predefined message for a specified time. Examples are
shown below.
Figure 3-5 - DynaPro Mini Messages
An error will be reported in ACKSTS of Report 0x01 – Response ACK in the following cases:
Bad parameter (0x82)
System is not available (0x8A)
If no error occurs, when the command completes (message displayed, user cancelled, or timeout), the
device will do the following:
1) Clear the display
2) Return to the idle state
3) Send Report 0x27 – Display Message Done Report to the host
Table 3-7 - Usage Table for Report 0x07
Bit
7
6
5
4
3
2
1
0
Byte 0
0x07
Byte 1
Wait Time in seconds, (1 – 255; 0 = infinite wait time)