3 - Command Set

DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)


Page 34

Bit

7

6

5

4

3

2

1

0

Enter

Right

Middle

Left

Byte 4

Tones:
Start Transaction Tones Only:
0 = No sound
1 = One beep
2 = Two beeps
Start Transaction & Timeout Tones:
100 = No start beep, no timeout
101 = One start beep, no timeout
102 = Two start beep, no timeout

3.4.7 Report 0x07 – Display Message

This command causes the device to display a predefined message for a specified time. Examples are
shown below.

Figure 3-5 - DynaPro Mini Messages

An error will be reported in ACKSTS of Report 0x01 – Response ACK in the following cases:

Bad parameter (0x82)

System is not available (0x8A)


If no error occurs, when the command completes (message displayed, user cancelled, or timeout), the
device will do the following:

1) Clear the display

2) Return to the idle state

3) Send Report 0x27 – Display Message Done Report to the host

Table 3-7 - Usage Table for Report 0x07

Bit

7

6

5

4

3

2

1

0

Byte 0

0x07

Byte 1

Wait Time in seconds, (1 – 255; 0 = infinite wait time)