3 - command set – MagTek DynaPro Mini Programmer's99875629 User Manual
Page 62
3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)
Page 62
Important usage notes regarding getting and setting BLE module properties are included in section 3.4.23
Report 0x1D – Set BLE Module Control Data (BLE Only).
Table 3-60 - Usage Table for Report 0x2D
Byte
Description
Byte 0
0x2D
Byte 1
Control data length (defined in Appendix J)
Bytes 2 to (2
+ control data
length – 1)
Control data (defined in Appendix J)
Bytes (2 +
control data
length) to 63
Padding. All bytes are zeros.
3.5.12 Report 0x2E – Clear Text User Data Entry Response Report
This event is triggered by Report 0x1F – Request Clear Text User Data Entry, which causes the device
to send clear text User data to the host after the user has successfully entered data. It is only available in
firmware revision C12 or newer.
Table 3-61 - Usage table for Report 0x2E
Byte
Description
Byte 0
0x2E
Byte 1
Operation Status (see Appendix C Status and Message Table)
Byte 2
User Data Mode
0 = SSN (9 digits)
1 = Zip Code (5 digits)
2 = Birthdate (8 digits, MMDDYYYY format)
3 = Birthdate (6 digits, MMDDYY format)
Byte 3
Length of data
Bytes 4 – 12 Clear Text User Data block – only the indicated number of bytes is meaningful, other
bytes should be ignored.