Tag
Description
Default (HEX)
Forma
t
Length
DFDF42
PIN Encryption Type:
0xxx xxxx = Fixed key
1xxx xxxx = DUKPT key
xx00 xxxx = TDES
xx01 xxxx = AES
xxxx xx00 = Data variant
xxxx xx01 = PIN variant
xxxx xx10 = MAC variant
*
b
1
DFDF43
MagnePrint Status Data
*
b
4
DFDF44
Encrypted PAN Data
*
b
var
DFDF50
MSR KSN
*
b
10
DFDF51
MSR Encryption Type (see DFDF42 for bit
definitions)
*
b
1
DFDF52
Card Status (Report 0x22) (Not supported)
-
-
-
DFDF53
Fallback Indication (0=No fallback or missing
tag, 1-Fallback used)
*
b
1
DFDF54
MAC KSN
*
b
10
DFDF55
MAC Encryption Type (see DFDF42 for bit
definitions)
*
b
1
DFDF56
Encrypted Transaction Data KSN
*
b
10
DFDF57
Encrypted Transaction Data Encryption Type
(see DFDF42 for bit definitions)
*
b
1
DFDF58
Number of Bytes of Padding in F8
*
b
1
DFDF59
Encrypted Data Primitive
*
b
var
DFDF61
BIN Table Slot 1
00 00 00 00 00 00 b
6
DFDF62
BIN Table Slot 2
00 00 00 00 00 00 b
6
DFDF63
BIN Table Slot 3
00 00 00 00 00 00 b
6
DFDF64
BIN Table Slot 4
00 00 00 00 00 00 b
6
DFDF65
BIN Table Slot 5
00 00 00 00 00 00 b
6
DFDF66
BIN Table Slot 6
00 00 00 00 00 00 b
6
DFDF67
Acquirer Terminal Config – Fallback
(0=Fallback Not Supported, 1=Fallback
Supported)
01
b
1
DFDF68
Acquirer Terminal Config - PIN Bypass
(0=PIN Bypass Not Supported, 1-PIN Bypass
Supported)
01
b
1
DFDF70
Terminal Action Code - Default
00 00 00 00 00 00 b
5