beautypg.com

Table 3-18 ), E table 3-18, 3 - command set – MagTek DynaPro Mini Programmer's99875629 User Manual

Page 41

background image

3 - Command Set

DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)


Page 41

Bit

7

6

5

4

3

2

1

0

Byte 2

Key Status, if Info ID < 0x80:
0 = Empty (default)
1 = OK
2 = Exhausted
Key Status, if Info ID = 0x80:
0 – 5 = KCV type (see Table 3-18)

Byte 3

Data length (see Table 3-18); default value is 0

Byte
4..63

Block data

Table 3-18 – Block Data Returned for Report 0x0E

Info ID

Key

Status

Data

length

Data

Description

0x00

1

lbllen*

Auth key label

If auth key exists

0x01,0x02 2

20

KSN

If no more keys

0x01

1

20

KSN

PIN key

0x02

1

20

KSN

MSR key

0x03

1

<=59

SN & subject’s DN**

If PIN cert exists

0x04

1

<=59

SN & subject’s DN**

If MSR cert exists

0x05

1

<=19

Label and KCV

If auth key exists

0x06

1

<=19

Label and KCV

If fixed key exists

0x07

1

<=59

List of 2 byte items
(type,MID)

ID list of installed MID secrets

0x08

1

12

Customer ID,
(4 byte integer)
Signing Sequence
Number,
(4 byte integer)
Upgradability Options,
(4 byte integer)

0x0000000 is Generic Customer
Signing Sequence typically starts
at 0x00000000 and must advance
with each upgrade.
Upgradability values:
0x00000000 – Generic Only
0x00000001 – Specific Only
0x00000002 – Generic or
Specific

0x09

1

<=19

Label and KCV

Acquirer Master Key

0x10

1

4 x 3

4 slots for bitmap data
[status + 2 bytes CRC]
status: 0 = not loaded
1 = loaded

Bitmap data status and its CRC

0x20 -
0x29

-

-

-

RESERVED