beautypg.com

3 - command set – MagTek DynaPro Mini Programmer's99875629 User Manual

Page 36

background image

3 - Command Set

DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)


Page 36

Bit

7

6

5

4

3

2

1

0

Config
0=unlocked
1=locked

Bitmap
0=unlocke
d
1=locked

Tests
Allowed
0=disable
1=enable

iAP Config
Allowed
0=unlocked
1=locked

Clear
Text
User
Data
0=no
1=yes

0

MSR
encrypt
ion
variant
0=PIN
1=DAT
A

Requir
e auth
0=no
1=yes

Byte 2

Allow Charging in iAP mode
0x00 = disabled, default
0x01 = enabled

Byte 3

Mask Configuration (default value = 0xC0, all enabled except MS2.0)

ISO Mask
0 = disable
1 = enable

Check
Digit
0 = disable
1 = enable

MS2.0 Enable
00 = MS2.0 disabled
10 = MS2.0 enabled

Track 2 Data

Track 1 Data

Error

Blank

Error

Blank

Byte 4

MSR Card Configuration (default value = 0xD5, all enabled)

AAMVA
Card
0 = disable
1 = enable

Non-
finance
card option

Track 3 Data

Track 2 Data

Track 1 Data

00=disabled
01=enabled
11=required

00=disabled
01=enabled
11=required

00=disabled
01=enabled
11=required

Byte 5

Mask Character (factory setting is ‘0’)

Byte 6

Leading length to leave unmasked
In SRED, maximum length = 6
In MS2.0 format, if >8, set to 8; if <5, set to 5

Trailing length to leave unmasked
In SRED, maximum length = 4
Ignored in MS2.0 format

Byte 7

EMV L2 ICS Configuration (Default = 0x01)
Note: This setting is ignored when EMV Mode is disabled.

EMV L2 ICS Configuration
0000 = No L2 capability
0001 = Configuration 1C
0010 = Configuration 2C
0011..1111 = Reserved

Byte 8

0x00


Notes for Byte 3, bits 0 – 3:

These four bits can contain any combination of values from 0000 to 1111.

If Error = 0, the device will build MS2.0 format track data (if MS2.0 is enabled) if at least one track

contains good data – the indicated track may contain errors.