beautypg.com

3 - command set – MagTek DynaPro Mini Programmer's99875629 User Manual

Page 42

background image

3 - Command Set

DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)


Page 42

Info ID

Key

Status

Data

length

Data

Description

0x50

1

9

Keypad sensitivity
Tamper sensitivity
Key on threshold
Key off threshold
4 bytes keypad threshold
Keypad calibration result

Keypad values

0x51

1

8

Parameter1 (2 bytes)
Parameter2 (2bytes)
Z ON pen (1 byte)
Z OFF pen (1 byte)
Reserved for future use
(2 bytes)

Signature Capture configuration

0x60 –
0x70

1

<=59

SN & subject’s DN**

If associated CA cert exists***

0x71 –
0x7F

1

<=59

SN & issuer’s DN**

If associated CA cert exists***

0x80

kcv_type=0 4

KCV value

KCV**** for Auth key

0x80

kcv_type=1 4

KCV value

KCV for PIN key

0x80

kcv_type=2 4

KCV value

KCV for MSR key

0x80

kcv_type=3 4

KCV value

KCV for fixed PIN key

0x80

kcv_type=4 4

Hash value

Dev auth key signed by PIN cert

0x80

kcv_type=5 4

Hash value

Dev auth key signed by MSR cert

0x80

kcv_type=7 6

KCV value

KCV for MID secret

0x80

kcv_type=9 4

KCV value

KCV for Acquirer Master key

0x80

All other
kcv_types

0

KCV****

* lbllen = auth key’s label length
** SN = serial number of cert; DN = distinguished names of subject or issuer of cert; Data length varies
with SN and DN length; max length is 59.
*** its corresponding CA cert
**** KCV = Key Check Value, where the lowest 6 digits are valid